CanadianSolar CSI-7K-S22002-ED User Manual Download Page 22

 

  1 / 2

 

CT Installation Manual Guide 

 

(Part No.: 2809000900      Release Date: August, 2020) 

1. Scope 

CSI inverters integrate the export limitation function, to use this function, please read this installation guide to install the CT sensor and set the inverter. 
This CT sensor applies to PV inverter models: CSI-3K-S22002-E, CSI-5K-S22002-E; CSI-3K-S22002-ED, CSI-5K-S22002-ED; CSI-7K-S22002-E, CSI-8K-S22002-E, 
CSI-9K-S22002-E; CSI-7K-S22002-ED, CSI-8K-S22002-ED, CSI-9K-S22002-ED. 

2. CT Specification 

 

Model Name 

CTSA016-100A/33.33mA 

Rated primary current 

100 A 

Rated secondary current 

33.33 mA 

Secondary load 

10 Ω 

Power frequency withstand voltage  4000V / 10S, 1mA 

Insulation resistance 

100MΩ @ 500Vdc 

 Accuracy 

± 0.5 % 

Maximum current 

120 A continuous 

Environmental protection 

ROHS 

Dotted terminal 

P1 and red cable 

Dimension (W x H x D, mm) 

30.5 X 49 X 34 mm 

Signal cable length 

5 m (not including CT sensor) 

FIG1. Outline and Dimensions of CT

 

3. CT installation 

3.1 System diagram. 

L

N PE

L

N

PE

~

CT

CT/METER

L

N PE

Load

 

FIG.2 Electrical and signal connection diagram 

3.2 Wiring signal cable 
3.2.1 Wiring signal connector 
1) Diagram of connector, as per FIG.3.   
2) Prepare the CT (signal) cable 
Remove the CT cable’s jacket about 23mm, and then strip the wire insulation layer by about 7mm, as per FIG.4. 

 

                               

16

7

 

Pressure Nut        Sealing Ring      Threaded Sleeve          Plug (Meter Pins and shell)                                                FIG.4 Strip Signal Cable 

FIG.3 Components of Connector 
 

 
 

 

 

 

3) Insert the conductors into the corresponding pins of the plug, and then fix the conductors by screws firmly. 

Tool: Phillips screwdriver #1.        Torque: 0.6~0.8N.m. 
 
 

Recommend the specification of the signal cable

 

Cable Type 

Conductor Cross-Sectional Area 

Outer Diameter 

Two cores cable. 

0.2-0.75mm

2

 (24~18AWG) 

3.5~5.5mm 

Note: Signal cable length (not including CT sensor) is 5m.    For extension cables, please see above specifications. 

21.0

16.0

49.0

30.5

30.7

34.0

Signal cable 
 

Note: The arrow has to be pointing to 
the grid side, not the load side.

 

 
 

Summary of Contents for CSI-7K-S22002-ED

Page 1: ...CSI 7K S22002 ED CSI 8K S22002 ED CSI 9K S22002 ED PV Inverter User Manual Part No 2809001100 Release Date September 2020...

Page 2: ...t Introduction 3 3 2 Appearance 3 3 3 Product Nameplate 4 4 Storage 4 5 Unpackaging and Inspection 5 6 Installation 5 6 1 Basic Installation Requirements 5 6 2 Mounting Wall mounting Bracket 7 6 3 Ins...

Page 3: ...nance 14 12 Trouble Shooting 15 12 1 Warning 15 12 2 Errors 15 13 Handling the Inverter 16 13 1 Removing Inverter 16 13 2 Packing Inverter 16 13 3 Disposing Inverter 16 ANNEX A Acronyms and Abbreviati...

Page 4: ...roduct lists and documents published on our website at http www canadiansolar com as these lists are updated on a regular basis 1 3 Limitation of Liability Canadian Solar Inc shall not be held respons...

Page 5: ...iar with the safety specification about the electrical system 3 Be familiar with the local requirements rules and regulations 4 Understand the composition and working principles of the grid tied PV sy...

Page 6: ...odules DC switch inverter AC switch electricity meter and local grid The PV power system diagram is shown as FIG 3 1 KWH PV Modules DC Switch Inverter AC Switch Electricity Meter Utility Grid FIG 3 1...

Page 7: ...k the inverter Storage temperature 40 C 70 C Storage humidity 0 100 RH Non Condensing The stored warehouse should be clean well ventilated and non corrosive gas meanwhile it should be in a state of un...

Page 8: ...st be strong enough to bear the inverter s weight for a long period time Please check the inverter s weight in the product specification of ANNEX B 3 The inverter is protected to IP65 can be installed...

Page 9: ...ode Recommended 12 Install the inverter vertically or at a maximum backward tilted angle of 15 degrees to facilitate heat dissipation 15 FIG 6 5 Installation Angle Requirements 13 Do not install the i...

Page 10: ...G 6 6 237 45 164 74 5 250 374 45 164 74 5 250 FIG 6 6 Drilling Positions W x H 399 x 583mm 2 Knock expansion anchors into the corresponding four holes and then fix the wall mounting bracket to the wal...

Page 11: ...supplied 7 3 Meter CT Connection Optional The inverter has integrated export limitation functionality To use this function a power meter or a CT must be installed For installation and operation metho...

Page 12: ...I Install an independent two pole circuit breaker at the output side of the inverter for protection the recommended AC circuit breaker specifications are as follows Inverter type AC circuit breaker sp...

Page 13: ...to the polarities to make sure the correct assembling FIG 7 7 AC receptacle FIG 7 8 Installing the AC Connector 7 6 Wiring DC Input Note The DC connectors are in paired negative and positive ones Pay...

Page 14: ...e crimping pliers as per FIG 7 12 Ensure the conductors completely wrapped without loosening or damage FIG 7 11 Strip the Cable Insulating Layer FIG 7 12 Crimp the Contact 3 Insert the crimped contact...

Page 15: ...with a RS485 to usb port converter via RS485 serial line and then connect this module to PC 9 Commissioning Inverter 9 1 Checking Electrical 1 Check PE connections with multi meter To make sure all th...

Page 16: ...enerated by the PV modules If such fault occurs frequently please contact the maintenance personnel Note For the monitoring and local APP information please refer to documents published on our website...

Page 17: ...pments or the more recent revision of the manual with has been clearly and thoroughly understood Items Methods Period System clean Check the temperature and dust of the inverter Clean the inverter enc...

Page 18: ...ted grid 1 Turn off DC switch remove AC connector measure the voltage between fire line and the zero line then check if it is consistent with the grid connected specification of inverter 2 Inconsisten...

Page 19: ...y error Minor F 118 Power grid voltage detection consistency error Minor F 123 Secondary memory failure 1 Restart the inverter 2 If error message still exists contact Customer service F 124 Clock fail...

Page 20: ...packet radio service LED light emitting diode MPPT maximum power point tracking PC personal computer PE protecting earthing PV photovoltaic RCD residual current protective device RCM residual current...

Page 21: ...an Efficiency 97 5 97 5 97 5 MPPT Efficiency 99 9 99 9 99 9 Safety Protection DC SPD Type II DC Switch Integrated Anti Islanding Protection Integrated DC Reverse Protection Integrated Insulation Monit...

Page 22: ...ng CT sensor FIG1 Outline and Dimensions of CT 3 CT installation 3 1 System diagram L N PE L N PE CT CT METER L N PE Load FIG 2 Electrical and signal connection diagram 3 2 Wiring signal cable 3 2 1 W...

Page 23: ...t slipping as per FIG 9 4 Check the current and current direction turn on power FIG 7 Open the buckle FIG 8 Install the CT FIG 9 Fix the CT 3 4 Setting on the inverter default setting is OFF 1 Enter C...

Page 24: ...iagram Note The meter has to be installed to the grid side L L N N 5 6 7 8 L N PE L N PE L N PE Load CT Meter FIG 2 Electrical and Signal Connection Diagram 3 2 Wiring signal cable 3 2 1 Wiring signal...

Page 25: ...Pro APP 2 Enter the Local Mode as per FIG 8 3 Scan the QR code of WiFi stick or input the serial number of WiFi stick manually Then connect to the AP of WiFi stick as per FIG 9 4 Enter the Parameters...

Page 26: ...6 P 1 519 837 1881 F 1 519 837 2550 Sales Inquiries Email info canadiansolar com Customer Support Email service ca canadiansolar com This manual is subject to change without prior notification Copyrig...