background image

 

 

 

3

 / 

25

 

 

3 Product Overview 

3.1 Product Introduction 

The inverters are single-phase gird-connected PV string inverters without transformer, which can convert the DC power 
from the photovoltaic (PV) strings into alternating current (AC) power, and feed the power into the power grid. 
This document involves the following product models: 
CSI-3K-S22002-E, CSI-5K-S22002-E, CSI-5K-S22003-E. 
PV grid-connected system mainly includes PV modules, DC switch, inverter, AC switch, electricity meter, and local grid. 
The PV power system diagram is shown as FIG.3-1. 

KWH

     

PV Modules                          DC Switch                      Inverter                    AC Switch          Electricity Meter      Utility Grid   

FIG. 3-1 PV Power System Diagram 

3.2 Appearance 

Front view and bottom view   

 

A

C

B

D E F

G H

A

C

B

I

F E D

G H

 

FIG. 3-2 Front view and bottom view 

 

Object 

Name 

Description 

  LED indicator 

Indicates inverter operation status. 

  DC input connectors 

  DC disconnect switch 

Disconnect the DC current safely.   

CSI-3K-S22002-E 

CSI-5K-S22002-E 
CSI-5K-S22003-E 

Summary of Contents for CSI-5K-S22003-E

Page 1: ...CSI 3K S22002 E CSI 5K S22002 E CSI 5K S22003 E PV Inverter User Manual Part No 2809001703 Release Date July 2022...

Page 2: ..._______________________________________________________________________ 4 4 Storage_______________________________________________________________________________________5 5 Unpackaging and Inspection...

Page 3: ...______________________________ 19 1 Scope_______________________________________________________________________________________________ 19 2 CT Specification__________________________________________...

Page 4: ...s and documents published on our website at http www csisolar com as these lists are updated on a regular basis 1 3 Limitation of Liability CSI Solar Co Ltd shall not be held responsible for damages o...

Page 5: ...he safety specification about the electrical system 3 Be familiar with the local requirements rules and regulations 4 Understand the composition and working principles of the grid tied PV system 2 2 2...

Page 6: ...grid connected system mainly includes PV modules DC switch inverter AC switch electricity meter and local grid The PV power system diagram is shown as FIG 3 1 KWH PV Modules DC Switch Inverter AC Swi...

Page 7: ...Input Current 15 15 A dc Max Short Circuit Current 18 8 18 8 A dc Rated Output Power 5000W AC Nominal Voltage 220 240V ac AC Nominal Frequency 50 60Hz Max Output Current 25A ac Power Factor 0 99 0 8...

Page 8: ...nt is missing contact local dealer Note For details information about the components see the packing list document in the packing case 6 Installation 6 1 Basic Installation Requirements 1 Do not insta...

Page 9: ...dissipation and to ensure that no moisture can penetrate the product 15 FIG 6 5 Installation Angle Requirements 13 Do not install the inverter outdoors in salt sulfur or other corrosive areas The inve...

Page 10: ...nsion anchors into the corresponding four holes and then secure the bracket by using screws as per FIG 6 7 FIG 6 8 FIG 6 7 Install Expansion Anchors FIG 6 8 Fix Wall mounting Bracket 6 3 Installing In...

Page 11: ...r CT Connection Optional The inverter has integrated export limitation functionality To use this function a power meter or a CT must be installed For installation and operation methods see ANNEX C D f...

Page 12: ...n 0 9 leading to 0 9 lagging meanwhile need external SPI Install an independent two pole circuit breaker at the output side of the inverter for protection the recommended AC circuit breaker specificat...

Page 13: ...river to fix conductors firmly EXCEEDCONN type Torque 0 8N m PE L N L N PE A A A A DEVALAN type Torque 1 4N m L N PE B B B B N PE L FIG 7 5 AC Terminal Positions 3 Push the threaded sleeve into the pl...

Page 14: ...the insulation from each DC cable by 7mm Step 2 Assemble the cable ends with the crimping pliers Step 3 Lead the cable through cable gland and insert into the insulator until it snaps into place Gentl...

Page 15: ...n perform the wiring work 8 Communication 8 1 Communication Mode Multi communication patterns for option RS485 Built in module GPRS and WIFI with the communication port M16 8 2 External WiFi More deta...

Page 16: ...f the PV strings is greater than the Min DC input voltage but is lower than the DC start up input voltage Inverter cannot start up normally and cannot feed power into utility grid either 2 Checking Co...

Page 17: ...dertaken in the absence of proper tools test equipments or the more recent revision of the manual with has been clearly and thoroughly understood 12 Trouble Shooting When the inverter does not operate...

Page 18: ...check the grid layout 3 Consistent connect the AC connector turn on DC Switch inverter will restore the grid connection automatically 4 If error message still exists contact Customer service F 107 DC...

Page 19: ...section 10 and section 11 2 Remove all the connection cables from the inverter 3 Unscrew the fixing screws on both sides of the inverter 4 Remove the inverter from the bracket Note Before performing...

Page 20: ...evice DRM demand response mode LED light emitting diode MPPT maximum power point tracking PC personal computer PE protecting earthing PV photovoltaic RCD residual current protective device RCM residua...

Page 21: ...ection DC Switch Integrated Anti Islanding Protection Integrated DC Reverse Protection Integrated Insulation Monitoring Integrated AC Over Voltage Protection Integrated AC Over Current Protection Inte...

Page 22: ...al P1 and red cable Dimension W x H x D mm 30 5 X 49 X 34 mm Signal cable length 5 m not including CT sensor FIG 1 Outline and Dimensions of CT 3 CT installation 3 1 System diagram L N PE L N PE CT CT...

Page 23: ...The current direction muse be consistent with the arrow direction on the shell of CT 3 Fix the CT with cable tie to prevent slipping as per FIG 9 4 Check the current and current direction turn on pow...

Page 24: ...tallation Method Rail DIN 35mm FIG 1 Outline and Dimensions of Meter 3 Meter installation 3 1 System diagram Note The meter has to be installed to the grid side L L N N 5 6 7 8 L N PE L N PE L N PE Lo...

Page 25: ...r manual Tools Phillips screwdriver 2 Torque 1 2 1 6N m 3 4 Setting on the inverter default setting is OFF 1 Enter CSI CloudPro APP 2 Enter the Local Mode as per FIG 8 3 Scan the QR code of WiFi stick...

Page 26: ...Install the App Method 1 Scan the following QR Code to download and install the App according to the prompt information Method 2 Download and install the App through the following application stores G...

Page 27: ...24 25 Step 1 Open the CSI CloudPro APP Step 2 Select Local Mode then scan logger SN The mobile phone will connect to the collector automatically...

Page 28: ...onnection succeeds users can view the real time operating data of the inverter Step 4 Select Params enter the password 000000 and login the system Then users can view and modify parameters APP picture...

Page 29: ...Jiangsu China 215129 Sales Inquiries Email info csisolar com Customer Support Email service ca csisolar com This manual is subject to change without prior notification Copyright is reserved Duplicati...