Troubleshooting

Canadian Spa Customer Service

In the unlikely event that a customer experiences an issue we provide multiple channels to contact us. A specific ticket number will then be assigned to the 
customer/issue, which enables us to have all information in one place, from order status, any outstanding customer service issues to previous customer 
history. Based on the issue we will ship the replacement part to the customer. This is followed up with a short email to confirm that the job was completed to 
their satisfaction.

Live

chat

Email

Log

support

ticket

Phone

Support

agents

Solve 

over the 

phone 

Ship

parts

Service portal

Log a 

service ticket

Resolved

Question

or issue

Email: [email protected]

PROBLEM

1.  Power indicator light not on
  or beeping sound coming from  
 sauna

2.  Function indicator light not on

3.  Infrared Heater will not heat up

4.  Sauna room not maintaining  
  correct temperature

5.  Burning smell

6.  The light not working

EXPLANATIONS

• Power cord is not plugged-in
• The fuse is burned out
• Check or replace the fuse.
• Check temp probe in correct location
• The corresponding indicator light is    
  broken or burned out.
• The wiring or some electronic 
  component in the circuit has failed
• The heater is broken its life will be    
  shortened gradually from excessive use.
• The fuse is burned out.
• The wiring connection for the heater is  
  loose or in the wrong location.
• The circuit board is not functioning.
• Problem with heater.
• Incorrect setting on control panel
• The temperature sensor wire may be loose  
  or broken.
• Circuit problems causing burning of                  
  components in the electrical system.
• The light bulb is burned out.
• The bulb is not secured in the base
• The socket is broken.
• Problems with electrical control panel.

SOLUTIONS

• Check for power to the outlet.
• Check connection between power cord and main 
  control unit.
• Remove temperature sensor and reinstall 
• Repair or replace the control panel.

• Repair or replace what has failed in that circuit.

• Replace with a new heater of the same specifications.

• Check or replace the fuse.
• Check it, and reconnect tightly.

• Check power output on the circuit board
• See item #3
• Power sauna off and on to reset
• Check sensor wire connection and condition.
  Check to see if sensor head is visible inside the sauna room.

• Unplug sauna, check the voltage.

• Call your local service technician
• Replace light bulb.
• Make sure the bulb is tight enough to make 

  good contact in the light fixture.

• Replace it.
• Check or replace the panel.

Summary of Contents for Banff

Page 1: ...B A N F F S A U N A Banff 3 Person Sauna Owners Manual KY 10009 canadianspacompany com All Plug and Play models can be plugged into a standard indoor 13Amp socket no need for an electrician...

Page 2: ...persistent erythema reddening of the skin lasting more than a day persists after regular exposure to infrared radiation exposure should not be repeated and medical advice should be sought to prevent d...

Page 3: ...you are still too warm open the door until you feel comfortable or turn the set temperature down To absorb perspiration and keep the sauna tidy during the session place a towel on the bench and floor...

Page 4: ...tly more effective at reducing cellulite There is a direct link between the slowing of metabolic rates and the storage of toxins in fat cells Sauna use and far infrared heat can increase heart rate an...

Page 5: ...access to bolt in the back panel Sauna can be slid back after installation We recommend you assemble the sauna as close to its permanent position as possible 5 Back Panel x 1 Side Panel left x 1 Side...

Page 6: ...all clasps x 3 sets Wall clasps x 3 sets Wall clasps x 3 sets Assembly 6 Door side wall Back wall Handle Cool Handle system stainless steel door exterior handle and wood interior handle Assembly Aroma...

Page 7: ...the door panel on the base and align the clips on each side and attach Bench Heater Panel Slide into groves by pulling the walls slightly apart then connect the heater cables for the leg heater Bench...

Page 8: ...ey all have the same power output Each of the outlets is fused separately A B C D Control Box Heater wires C D C T R L Plug in T E M P C D C T R L Plug in TEMP Plug In CONTROL Plug In AMP Plug In LED...

Page 9: ...as been plugged in It will also start warming up the heater once the time and temperature has been set Hold the power button down to turn off sauna Interior Light Control This button will turn on and...

Page 10: ...he corresponding indicator light is broken or burned out The wiring or some electronic component in the circuit has failed The heater is broken its life will be shortened gradually from excessive use...

Page 11: ...tabolism and produces calming effect BLUE Calms breathing and heart rate Lowers blood pressure helps insomnia and headaches Reduces overall pain STRONG BLUE Reduces stress and nervous tension lubricat...

Page 12: ...cturer be liable for any special or consequential damages arising from the use of the product components and the parts attached or installed with it Nor for injury to any person any claims for damages...

Reviews: