Mounting
Method
Supplier
Clamp Image
Clamp Type & length
Clamp Quantity
& Location
Load (Pa)
Certification
Body
3-E-1
Powerway
Renewable Energy
Co.,Ltd
PW-CS-01(End clamp) /
PW-CS-02 (Middle clamp),
clamp length=130 mm
four clamps,
A=440±20 mm,
see illustration A
Downforce load≤2400 Pa
Uplift load ≤2400 Pa
VDE / CSA
3-E-2
PW-CS-01(End clamp) /
PW-CS-02 (Middle clamp),
clamp length=250 mm
four clamps,
A=440±20 mm,
see illustration A
Downforce load≤5400 Pa
Uplift load ≤2400 Pa
VDE / CSA
3-E-3
PW-CS-01(End clamp) /
PW-CS-02 (Middle clamp),
clamp length=100 mm
six clamps,
A=300±20 mm,
B=684±20 mm,
see illustration B
Downforce load≤2400 Pa
Uplift load ≤2400 Pa
VDE / CSA
3-E-4
PW-CS-01(End clamp) /
PW-CS-02 (Middle clamp),
clamp length=130 mm
six clamps,
A=300±20 mm,
B=684±20 mm,
see illustration B
Downforce load≤5400 Pa
Uplift load ≤2400 Pa
VDE / CSA
3-F-1
Akcome Metals
Technology
(Suzhou) Co.,Ltd.
AK-EC-DG (End clamp)
/ AK-MC-DG (Middle
clamp),
clamp length=130 mm
four clamps,
A=440±20 mm,
see illustration A
Downforce load≤2400 Pa
Uplift load ≤2400 Pa
VDE/CSA
3-F-2
AK-EC-DG (End clamp)
/ AK-MC-DG (Middle
clamp),
clamp length=250 mm
four clamps,
A=440±20 mm,
see illustration A
Downforce load≤5400 Pa
Uplift load ≤2400 Pa
VDE/CSA
3-F-3
AK-EC-DG (End clamp)
/ AK-MC-DG (Middle
clamp),
clamp length=100 mm
six clamps,
A=300±20 mm,
B=684±20 mm,
see illustra tion B
Downforce load≤2400 Pa
Uplift load ≤2400 Pa
VDE / CSA
3-F-4
AK-EC-DG (End clamp)
/ AK-MC-DG (Middle
clamp),
clamp length=130 mm
six clamps,
A=300±20 mm,
B=684±20 mm,
see illustration B
Downforce load≤5400 Pa
Uplift load ≤2400 Pa
VDE / CSA
The following clamps in table 4 have been approved
as compatible with Canadian Solar double glass
module CS3K-MS-FG and CS3K-P-FG.