| 21
Use 4 clamps with long center rail on the long side of
each module.
Two modules share one tube, portrait installation.
Bolting on long frame side using four innermost
mounting holes
Mounting rails run parallel to the long side frame.
Mounting rails fixed on torque tube (tracker).
Overlap support length of between rail and frame
A ≥ 730 mm
Center distance between clamps B ≥ 650 mm
Clamp length C ≥ 80 mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa
CS3W-PB-AG
Tube
Rail