MOBILE HOME SPECIFICATIONS
Your corn stove has been tested and listed for mobile home
installation. Please carefully follow the directions below and
note all pertinent specifications for your own installation.
NOTE: Check with your local building inspector or
qualified installation person to verify that all installation
specifications are being met with your mobile home
installation.
In addition to all previously detailed installation requirements, mobile home installations must meet the
following requirements:
INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.
Permanently bolt your stove to the floor
.
.
.
.
.
Electrically ground your stove or the pedestal to the steel frame of the home. Use a number 8
gauge copper wire or equivalent
The stove must have a permanent outside air source with a 1/4 inch screen over the inlet
When moving your mobile home, all exterior venting MUST BE REMOVED while the mobile home
is being relocated. Upon completion of relocation, all venting must be reinstalled and securely
fastened.
PL or L vent must be 3” or 4” and must extend a minimum of 36 inches above the roofline of the
mobile home and must be installed using a UL/ULC listed ceiling fire stop and rain cap
A - Floor Pad
B - Combustion Air Intake
C - Fresh Air Duct
D - Fresh Air Hood
E - Stove Exhaust
F - Pipe Adapter
G - Clean-Out Tee
H - Tee Support Bracket
I - Pipe
J - Fire Stop Spacer/
Ceiling Support
K - Roof Flashing/Storm
Collar
L - Rain Cap
CAUTION: DO NOT INSTALL IN ANY SLEEPING ROOM!
THE STRUCTURAL INTEGRITY OF THE MANUFACTURED
HOME FLOOR & CEILING/ROOF MUST BE MAINTAINED!
MOBILE HOME
CONFIGURATIONS
6
B
A
C D
G
H
I
J
K
L