background image

 

Indicator

 

The indicator flashes red several times after power-on. 

•  The indicator flashes red several times after power-on. 

•  After the device is turned on, the indicator light is white for about three 

seconds. During this period, press the FUNC button to enter the configuration 
mode. 

•  Under normal mining conditions, the indicator light is green 

•  The indicator light is 

yellow 

during system preparation 

•  The indicator iswhen the system is overheated 

•  When the system is running, press the FMS software or manually press the 

FUNC key. The indicator light is always white, press again to restore the 
original color. 

•  Restore factory settings: When power is on (before the indicator flashes 

), 

press the FUNC function button for five seconds, until the white light flashes 
to indicate success, then press RESET or disconnect the power to restart. 

Operation mode

 

The device has two modes of operation: “Normal Mode” and “Configuration Mode”. 

Normal mode 

In normal working mode, the device runs in this mode for most of the life cycle. In this 
mode, the network can use DHCP (dynamic acquisition) or static IP, and the factory 
setting is DHCP. 

 

Configuration mode

 

The device will enter this mode by pressing the FUNC key during the white light 
(about three seconds) after startup. In this mode, the IP address is static (address: 
192.168.168.168, subnet mask: 255.255.255.0). The built-in Web service of the 
device can be accessed through a PC browser to configure information such as the 
network, mine pool, and password. Set the PC to a static IP address: 
192.168.168.100 (or any other non-conflicting address on the same network 
segment), subnet mask: 255.255.255.0, connect to the same network as the device 
(under the same switch or router, or PC) Device network cable directly connected) 

Summary of Contents for AvalonMiner1066

Page 1: ...sonal safety please install and use it in strict accordance with the instructions You cannot modify the equipment and replace the parts yourself Do not use power supplies that exceed the rated voltage range Do not place the device in an unstable location When inspecting and repairing equipment please entrust a professional to operate When servicing equipment please ask a professional to operate Wh...

Page 2: ...Power Supply Connection Secure the adapter plate to the machine with six M3 4 screws as shown Push the power supply into the card slot as shown ...

Page 3: ... copper strip to the machine as shown below Plug the power supply 6pin plug into the 6pin socket of the machine as shown below Each machine is equipped with two network ports which can be connected in series with a network cable up to 12 units ...

Page 4: ...e second machine and the third machine are connected in series by the network cable C thereby performing multiple machines Series Button and indicator button RESET System reset button system reset does not affect network connection FUNC Function button can be used to restore the factory configuration enter the configuration mode switch the lighting status during operation etc ...

Page 5: ...ess then press RESET or disconnect the power to restart Operation mode The device has two modes of operation Normal Mode and Configuration Mode Normal mode In normal working mode the device runs in this mode for most of the life cycle In this mode the network can use DHCP dynamic acquisition or static IP and the factory setting is DHCP Configuration mode The device will enter this mode by pressing...

Page 6: ...an click Reboot on the left side of the console or manually power off and restart Don t forget to switch your network connection to prevent your device from accessing the internet Use the browser to revisit the modified IP address If the indicator is green the operation is correct System setting Access the built in web service of the device through a browser and access the device console after log...

Page 7: ...off the power again Mine pool setting The following figure shows the factory default settings The Work Mode can select either Normal Mode High Mode Low Power Mode or High Performance Mode When using High Performance mode please pay attention to the power supply with higher power output So as not to damage the hardware Note The mine pool configuration must be restarted after it has been saved Click...

Page 8: ... the left side of the console to set a new password and save it Firmware Update The upgrade package file format of this device is aup which can be downloaded through the official website or by contacting customer service The firmware upgrade of this device can be performed by FMS software ...

Page 9: ...bnormal damage of the device You can check and troubleshoot it yourself If the device is damaged and covered by warranty you can contact our after sales personnel for a quick return This product provides a warranty of 180 days from the time the user receives the goods but the following conditions will void the warranty Any physical damage caused by self removal of the device or other reasons inclu...

Reviews: