background image

VCO-6000-ADL

Machine Vision Computer

Summary of Contents for VCO-6000-ADL

Page 1: ...VCO 6000 ADL Machine Vision Computer...

Page 2: ...E Expansion 19 1 3 2 VCO 6000 ADL 4E 20 VCO 6000 ADL 4E Expansion 21 1 4 Mechanical Dimension 22 1 4 1 VCO 6000 ADL 3E 22 1 4 2 VCO 6000 ADL 4E 23 Chapter 2 Mechanical Specifications 24 2 1 Switch and...

Page 3: ...3 13 USB Configuration 95 3 3 14 Network Stack Configuration 96 3 3 15 CSM Configuration 97 3 3 16 NVMe Configuration 98 3 4 Chipset 99 3 4 1 System Agent SA Configuration 99 3 4 2 PCH IO Configuratio...

Page 4: ...part of this manual may be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying recording or information storage and retrieval systems without the prio...

Page 5: ...the power outlet Disconnect this equipment from the power before cleaning Use a damp cloth Do not use liquid or spray detergents for cleaning Avoid the dusty humidity and temperature extremes Do not p...

Page 6: ...erial number Description of your peripheral attachments Description of your software operating system version application software etc A complete description of the problem The exact wording of any er...

Page 7: ...e installation please ensure all the items listed in the following table are included in the package Item Description Q ty 1 Choosing one VCO 6000 ADL 3E Series VCO 6000 ADL 4E Series 1 2 Wall Mount K...

Page 8: ...er w LGA 1700 for Intel 12 13th Gen CPU R680E PCH 3x PCIe 2x 15mm NVMe 2x Power input Model No Product Description VCO 6000 ADL 4E Machine Vision Computer w LGA 1700 for Intel 12 13th Gen CPU R680E PC...

Page 9: ...th 3pin Terminal Block Plug 5 0mm Pitch 1 E09A22801 Adapter AC DC 24V 11 67A 280W with 3pin Terminal Block Plug 5 0mm Pitch 1 E09A36001 Adapter AC DC 24V 15A 360W with 3pin Terminal Block Plug 5 0mm P...

Page 10: ...Chapter 1 Product Introductions...

Page 11: ...image and vision measurement machine automation Delivering high quality durability and compact construction the systems leverages a reliable fanless and cable free configuration optimal thermal dissi...

Page 12: ...6 Gen4 2x PCIe x1 Gen3 6x HDD VCO 6000 ADL 3E 4B7M 2PWR 1x PCIe x16 Gen4 2x PCIe x1 Gen3 6x HDD 2x Power input VCO 6000 ADL 3E 2B15M 1x PCIe x16 Gen4 2x PCIe x1 Gen3 4x HDD VCO 6000 ADL 3E 2B15M 2PWR...

Page 13: ...6x HDD VCO 6000 ADL 4E 4B7M 2PWR 2x PCIe x16 Slot x8 Lane Gen 4 1x PCIe x4 x1 Lane Gen 3 6x HDD 2x Power input VCO 6000 ADL 4E 2B15M 2x PCIe x16 Slot x8 Lane Gen 4 1x PCIe x4 x1 Lane Gen 3 4x HDD VCO...

Page 14: ...1x PCIe x4 x1 Lane Gen 3 VCO 6000 ADL 4E SSD HDD Features Model No 1x Internal 2 5 SATA SSD HDD Bay support H 9mm 1x Removable 2 5 SATA HDD Bay support H 7mm Hot swappable VCO 6000 ADL 3E VCO 6000 AD...

Page 15: ...up to 4 Cores 12MB Cache up to 4 1 GHz 35W Intel Pentium G7400E 2 Cores 6MB Cache 3 6 GHz 46W Intel Pentium G7400TE 2 Cores 6MB Cache 3 0 GHz 35W Intel Celeron G6900E 2 Cores 4MB Cache 3 0 GHz 46W Int...

Page 16: ...t H 7mm Hot swappable 2x Removable 2 5 U 2 NVMe Bay support H 15mm Hot swappable Expansion Mini PCIe 1x Full size Mini PCIe 1x shared by 1x mSATA PCIe 1x PCIe x16 Gen4 2x PCIe x1 Gen3 Model No VCO 600...

Page 17: ...ower Protection OVP Over Voltage Protection OCP Over Current Protection Reserve Protection Environment Operating Temp 25 C to 70 C 35W CPU 25 C to 60 C 65W CPU Storage Temp 30 C to 85 C Relative Humid...

Page 18: ...iFi module USB 3 2 Gen 2 port 10 Gbps Used to connect USB 3 2 device Removable HDD Removable 2 5 SATA HDD Bay support H 7mm hot swappable DisplayPort Used to connect a DisplayPort monitor LAN Port Use...

Page 19: ...2PWR VCO 6000 ADL 3E 4B7M 2PWR VCO 6000 ADL 3E 2B15M 2PWR VCO 6000 ADL 3E 2N15M 2PWR Chapter 1 Product Introductions Storage optional 4B7M 4x Removable 2 5 SATA HDD Bay 2B15M 2x Removable 2 5 SATA HD...

Page 20: ...le USB 3 2 Gen 2 port 10 Gbps Used to connect USB 3 2 device Removable HDD Removable 2 5 SATA HDD Bay support H 7mm hot swappable DisplayPort Used to connect a DisplayPort monitor LAN Port Used to con...

Page 21: ...2PWR VCO 6000 ADL 4E 4B7M 2PWR VCO 6000 ADL 4E 2B15M 2PWR VCO 6000 ADL 4E 2N15M 2PWR Chapter 1 Product Introductions Storage optional 4B7M 4x Removable 2 5 SATA HDD Bay 2B15M 2x Removable 2 5 SATA HD...

Page 22: ...ADL 3E 4B7M VCO 6000 ADL 3E 2B15M VCO 6000 ADL 3E 2N15M VCO 6000 ADL 3E 2PWR VCO 6000 ADL 3E 4B7M 2PWR VCO 6000 ADL 3E 2B15M 2PWR VCO 6000 ADL 3E 2N15M 2PWR 22 Unit mm Chapter 1 Product Introductions...

Page 23: ...4E VCO 6000 ADL 4E 4B7M VCO 6000 ADL 4E 2B15M VCO 6000 ADL 4E 2N15M VCO 6000 ADL 4E 2PWR VCO 6000 ADL 4E 4B7M 2PWR VCO 6000 ADL 4E 2B15M 2PWR VCO 6000 ADL 4E 2N15M 2PWR 23 Unit mm Chapter 1 Product I...

Page 24: ...Chapter 2 Mechanical Specifications...

Page 25: ...IO 1 COM 1_2 DVI_I 1 CN 4 CN 3 PWR_SW 2 DC_IN 2 CPU 1 SODIMM 1 FAN_MCU PCH 1 M2_KB I2C FAN_SIO CAN 2 SMB CAN 1 JP 1 POWER 3 POWER 4 USB 3_2 USB 3_4 USB 3_3 AT_ATX SIM 1 CAR_PWR MIC_IN LINE_OUT USB 3_1...

Page 26: ...VCO 6000 ADL l User s Manual 26 Chapter 2 Mechanical Specifications 2 1 2 Bottom View SODIMM 2 SATA 3 SL 1 PCIE 2 SATA 1 SATA 2 PCIE 1 RESET SIM 2 BTB...

Page 27: ...or CN3 4 LAN and USB3 2 GEN 2 Ports X2 FAN_CPU FAN_SIO Smart FAN Connector PWR1 4 12V 5V Power Connector USB3_1 4 USB 3 2 Gen 2 USB 3 2 Gen 1 USB2 0 SIM1 SIM2 SIM Card Socket CAR_PWR PC mode CAR mode...

Page 28: ...Chapter 2 Mechanical Specifications 2 3 1 ESPI Debug Con JESPI 1 POWER 1 4 2 3 2 Power Con Pin Signal 1 5V 2 GND 3 GND 4 12V 1 4 1 2 9 10 Pin Signal Pin Signal 1 ESPI_IO_0 2 3 3V 3 ESPI_IO_1 4 ESPI_RE...

Page 29: ...r s Manual 29 Chapter 2 Mechanical Specifications 2 3 3 DC IN 1 9V 48V DC IN 1 DC IN 2 2 3 4 DC IN 2 9V 48V Pin Signal 1 9V 48V 2 9V 48V 3 9V 48V 4 GND 5 GND 6 GND 1 5 Pin Signal 1 9V 48V 2 9V 48V 3 G...

Page 30: ...Signal 1 DCD 2 DSR 3 RXD 4 RTS 5 TXD 6 CTS 7 DTR 8 RI 9 GND 10 GND RS232 RS422 RS485 Connector 2x5 10 pin box header 2 0mm pitch Pin Signal RS422 485 Full Duplex Definition RS485 Half Duplex Definitio...

Page 31: ...VCO 6000 ADL l User s Manual 31 Chapter 2 Mechanical Specifications COM 3 COM 4 Pin Signal Pin Signal 1 DCD 2 DSR 3 RXD 4 RTS 5 TXD 6 CTS 7 DTR 8 RI 9 GND 10 GND COM Con 1 9 2 10...

Page 32: ...ecifications COM 1_2 Pin RS232 Definition RS422 485 Full Duplex Definition RS485 Half Duplex Definition 1 DCD TX DATA 2 RxD TX DATA 3 TxD RX 4 DTR RX 5 GND GND GND 6 DSR 7 RTS 8 CTS 9 RI 1 5 6 9 1 5 6...

Page 33: ...VCO 6000 ADL l User s Manual 33 Chapter 2 Mechanical Specifications 2 3 6 SF100 SPI Con JP 1 Switch Definition 1 Power 3V 2 GND 3 CS 4 CLK 5 MISO 6 MOSI 7 NC 8 SPI_GATE 1 2 7 8...

Page 34: ...anical Specifications 2 3 7 AT ATX Power Mode Switch AT_ATX Switch Definition 1 2 Left ATX Power Mode Default 2 3 Right AT Power Mode 2 3 8 PC Car Mode Switch CAR_PWR Switch Definition 1 2 Left PC Pow...

Page 35: ...pecifications 2 3 9 Line out Jack Green Connector Type 5 pin Phone Jack LINE_OUT Switch Definition 1 GND 2 OUT_R 3 GND 4 GND 5 OUT_L MIC_IN Switch Definition 1 GND 2 MIC_R 3 GND 4 GND 5 MIC_L 2 3 10 M...

Page 36: ...6 Chapter 2 Mechanical Specifications 2 3 11 Clear BIOS Switch CLR_CMOS Switch Definition 1 2 Left Normal Status Default 2 3 Right Clear BIOS PWR_SW 1 Switch Definition 1 NC 2 Power Button 3 NC 4 GND...

Page 37: ...2 Mechanical Specifications 2 3 13 Remote Power Switch Type Terminal Block 1x2 2 pin 3 5mm pitch PWR_SW 2 PWR_SW 3 Pin Definition 1 Power Button 2 PWR_LED 3 HDD_LED 4 GND 2 3 14 For WCO 6000 ADL 2 1...

Page 38: ...cal Specifications 2 3 15 Reset Button RESET Switch Definition 1 2 RESET 3 4 GND 2 3 16 USB 3 1 Connector GEN2 x4 ports Type A USB 3_1 USB 3_2 USB 3_3 USB 3_4 Pin Definition 1 5V 2 USB2_D 3 USB2_D 4 G...

Page 39: ...ser s Manual 39 Chapter 2 Mechanical Specifications 2 3 17 USB3 0 Connector 2x5 10 pin header 2 0mm pitch CN 1 Switch Definition 1 5V 2 USB3_TX 3 USB_D 4 USB3_TX 5 USB_D 6 GND 7 GND 8 USB3_RX 9 NC 10...

Page 40: ...L l User s Manual 40 Chapter 2 Mechanical Specifications 2 3 18 USB2 0 Connector 2x5 10 pin box header 2 0mm pitch USB 2_L Switch Definition 1 NC 2 5V 3 NC 4 USB2_D 5 NC 6 USB2_D 7 NC 8 GND 9 NC 10 GN...

Page 41: ...SB 3 1 ports CN3 CN4 Pin Definition Pin Definition Pin Definition 1 5V 10 5V 20 LAN1_MDI0P 2 USB2_D1 11 USB2_D2 21 LAN1_MDI0N 3 USB2_D1 12 USB2_D2 22 LAN1_MDI1P 4 GND 13 GND 23 LAN1_MDI2P 5 USB3_RX1 1...

Page 42: ...nition 1 DVI_TX2 16 DVI Hot Plug Detect 2 DVI_TX2 17 DVI_TX0 3 GND 18 DVI_TX0 4 NC 19 GND 5 NC 20 VGA_DDC_CLOCK 6 DVI_DDC_CLOCK 21 VGA_DDC_DATA 7 DVI_DDC_DATA 22 GND 8 VGA VSYNC 23 DVI_TXCLK 9 DVI_TX1...

Page 43: ...lay Port Connector DP 1 DP 2 Pin Definition Pin Definition 1 DP_LANE0_P 11 GND 2 GND 12 DP_LANE3_N 3 DP_LANE0_N 13 GND 4 DP_LANE1_P 14 GND 5 GND 15 DP_AUX_P 6 DP_LANE1_N 16 GND 7 DP_LANE2_P 17 DP_AUX_...

Page 44: ...igital Input Output Connector Type Terminal Block 2x9 18 pin 3 5mm pitch DIO Pin Definition Pin Definition 1 DIN1 2 DOUT1 3 DIN2 4 DOUT2 5 DIN3 6 DOUT3 7 DIN4 8 DOUT4 9 DIN5 10 DOUT5 11 DIN6 12 DOUT6...

Page 45: ...VCO 6000 ADL l User s Manual 45 Chapter 2 Mechanical Specifications CAN1 CAN2 Pin Signal 1 CAN_H 2 CAN_L FAN_SIO Switch Definition 1 GND 2 12V 3 Sense 4 Control 1 2 1 4...

Page 46: ...VCO 6000 ADL l User s Manual 46 Chapter 2 Mechanical Specifications FAN_MCU Pin Signal 1 GND 2 12V 3 Sense 4 Control 1 4 For FAN_MCU RT 1 2 TEMP1...

Page 47: ...VCO 6000 ADL l User s Manual 47 Chapter 2 Mechanical Specifications BH 1 Pin Signal 1 3 3V 2 PLTRST 3 SLP S4 4 SLP S5 5 RSTBTN 6 GND I2C Switch Definition 1 I2C_DATA 2 I2C_CLK 3 GND 1 6 1 3...

Page 48: ...VCO 6000 ADL l User s Manual 48 Chapter 2 Mechanical Specifications SMB Pin Signal 1 SMB_DATA 2 SMB_CLK 3 GND 1 3...

Page 49: ...er LED Status Pin Definition 1 POWER LED 2 POWER LED Link LED Status CN3 Definition Steady Orange 1 Gbps Network Link Steady Green 100 Mbps Network Link Off 10 Mbps Network Link HDD_LED1 HDD Access LE...

Page 50: ...VCO 6000 ADL l User s Manual 50 Chapter 2 Mechanical Specifications LED Status WDT_LED WDTOUT LED Status Pin Definition 1 WDTOUT LED 2 WDTOUT LED...

Page 51: ...nual 51 Chapter 2 Mechanical Specifications 2 3 24 Top size SIM Card Socket SIM1 Top size for M 2 B Key Pin Definition Pin Definition C1 UIM_PWR C6 UIM_VPP C2 UIM_RESET C7 UIM_DATA C3 UIM_CLK CD NC C5...

Page 52: ...l 52 Chapter 2 Mechanical Specifications 2 3 25 Bottom size SIM Card Socket SIM2 Bottom size for Mini PCIe Pin Definition Pin Definition C1 UIM_PWR C6 UIM_VPP C2 UIM_RESET C7 UIM_DATA C3 UIM_CLK CD NC...

Page 53: ...ess mSATA Socket MINIPCIE Pin Definition Pin Definition 1 WAKE 2 3 3V 3 NC 4 GND 5 NC 6 1 5V 7 CLKREQ 8 UIM_PWR 9 GND 10 UIM_DATA 11 REFCLK 12 UIM_CLK 13 REFCLK 14 UIM_RST 15 GND 16 UIM_VPP 17 NC 18 G...

Page 54: ...nical Specifications Pin Definition Pin Definition 29 GND 30 SMB_CLK 31 TxN 32 SMB_DATA 33 TxP 34 GND 35 GND 36 USB2_D 37 GND 38 USB2_D 39 3 3V 40 GND 41 3 3V 42 NC 43 GND 44 DEVSLP 45 NC 46 NC 47 NC...

Page 55: ...1 GND 2 3 3VAUX 3 USB2_D 4 3 3VAUX 5 USB2_D 6 NC 7 GND 8 I2S2_SCLK 9 CNV_WR_1_DN 10 CNV_RF_RESET 11 CNV_WR_1_DP 12 I2S2_RXD 13 GND 14 MODEM_CLKREQ 15 CNV_WR_0_DN 16 NC 17 CNV_WR_0_DP 18 GND 19 GND 20...

Page 56: ...45 GND 46 CNV_MFUART2_TXD 47 REFCLK0 48 CNV_MFUART2_RXD 49 REFCLK0 50 SUSCLK 51 GND 52 PERST0 53 NC 54 M2_KEY E_BT_DIS2 55 WAKE0 56 M2_KEY E_WIFI_DIS1 57 GND 58 SMBDATAS_DUAL 59 CNV_WT_1_DN 60 SMBCLK...

Page 57: ...nition 1 CONFIG_3 2 3 3V 3 GND 4 3 3V 5 GND 6 FULL_CARD_POWER_OFF 7 USB_D 8 W_DISABLE1 9 USB_D 10 WWAN_LED 11 GND 20 NC 21 CONFIG_0 22 NC 23 GPIO_11 0 1 8V 24 NC 25 DPR 26 NC 27 GND 28 P_UIM_VPP 29 PE...

Page 58: ...n0 SATA B 42 NC 43 PERp0 SATA B 44 NC 45 GND 46 NC 47 PETn0 SATA A 48 NC 49 PETp0 SATA A 50 PCIE_RST_N 51 GND 52 PCIE_CLKREQ_N 53 PCIE_REFCLK_M 54 PCIE_WAKE_N 55 PCIE_REFCLK_P 56 NC 57 GND 58 NC 59 NC...

Page 59: ...in Definition B1 12V A1 FAN_P4 B2 12V A2 12V B3 12V A3 12V B4 GND A4 GND B5 SMB_CLK A5 NC B6 SMB_DATA A6 NC B7 GND A7 NC B8 3 3V A8 NC B9 NC A9 3 3V B10 3 3VAUX A10 3 3V B11 WAKE A11 RESET B12 FAN_P3...

Page 60: ...3 30 PCI Express x16 Slot PCIE 1 Pin Definition Pin Definition B1 12V A1 NC B2 12V A2 12V B3 12V A3 12V B4 GND A4 GND B5 SMB_CLK A5 NC B6 SMB_DATA A6 NC B7 GND A7 NC B8 3 3V A8 NC B9 NC A9 3 3V B10 3...

Page 61: ...7 RxN0 B18 GND A18 GND B19 TxP1 A19 NC B20 TxN1 A20 GND B21 GND A21 RxP1 B22 GND A22 RxN1 B23 TxP2 A23 GND B24 TxN2 A24 GND B25 GND A25 RxP2 B26 GND A26 RxN2 B27 TxP3 A27 GND B28 TxN3 A28 GND B29 GND...

Page 62: ...ND B43 GND A43 RxP6 B44 GND A44 RxN6 B45 TxP7 A45 GND B46 TxN7 A46 GND B47 GND A47 RxP7 B48 NC A48 RxN7 B49 GND A49 GND B50 TxP8 A50 NC B51 TxN8 A51 GND B52 GND A52 RxP8 B53 GND A53 RxN8 B54 TxP9 A54...

Page 63: ...5 GND A65 RxN11 B66 TxP12 A66 GND B67 TxN12 A67 GND B68 GND A68 RxP12 B69 GND A69 RxN12 B70 TxP13 A70 GND B71 TxN13 A71 GND B72 GND A72 RxP13 B73 GND A73 RxN13 B74 TxP14 A74 GND B75 TxN14 A75 GND B76...

Page 64: ...ot PCIE LAN_L LAN_R Pin Definition Pin Definition B1 12V A1 NC B2 12V A2 12V B3 12V A3 12V B4 GND A4 GND B5 SMB_CLK A5 NC B6 SMB_DATA A6 NC B7 GND A7 NC B8 3 3V A8 NC B9 NC A9 3 3V B10 3 3VAUX A10 3 3...

Page 65: ...8 GND B29 GND A29 RxP3 B30 NC A30 RxN3 B31 NC A31 GND B32 GND A32 NC B33 9_48VSB_IN A33 9_48VSB_IN B34 9_48VSB_IN A34 9_48VSB_IN B35 9_48VSB_IN A35 9_48VSB_IN B36 9_48VSB_IN A36 9_48VSB_IN B37 9_48VSB...

Page 66: ...chanical Specifications 2 3 32 SATA with Power Connector Pin Definition 1 GND 2 TxP 3 TxN 4 GND 5 RxN 6 RxP 7 GND 8 NC 9 NC 10 DEVSLP 11 GND Pin Definition 12 GND 13 GND 14 5V 15 5V 16 5V 17 GND 18 GN...

Page 67: ...Pin Definition Pin Definition A1 NC B1 NC C1 NC D1 NC A2 NC B2 NC C2 NC D2 NC A3 GND B3 GND C3 GND D3 GND A4 RxP1 B4 RxP0 C4 TxP1 D4 TxP0 A5 RxN1 B5 RxN0 C5 TxN1 D5 TxN0 A6 GND B6 GND C6 GND D6 GND A...

Page 68: ...ition B1 GND A1 GND B2 TxP0 A2 RxP0 B3 TxN0 A3 RxN0 B4 GND A4 GND B5 TxP1 A5 RxP1 B6 TxN1 A6 RxN1 B7 GND A7 GND B8 RST 1 A8 CLKP1 B9 RST 2 A9 CLKN1 B10 GND A10 GND B11 RST 3 A11 CLKP2 B12 RST 4 A12 CL...

Page 69: ...xN3 B19 GND A19 GND B20 TxP4 A20 RxP4 B21 TxN4 A21 RxN4 B22 GND A22 GND B23 TxP5 A23 RxP5 B24 TxN5 A24 RxN5 B25 GND A25 GND B26 PRSNT 1 A26 CLKP3 B27 PRSNT 2 A27 CLKN3 B28 GND A28 GND B29 RST 3 A29 CL...

Page 70: ...Chapter 3 BIOS Setup...

Page 71: ...unctions you can make changes to You can use the arrow keys to select the item The on line description of the highlighted setup function is displayed at the bottom of the screen General Help F1 The BI...

Page 72: ...in setup screen is showed as following when the setup utility is entered System Date Time is set up in the Main Menu System Date Set the system date Please use Tab to switch between data elements Syst...

Page 73: ...VCO 6000 ADL l User s Manual 3 3 Advanced Setup 73 Chapter 3 BIOS Setup...

Page 74: ...covered it will be enabled by default Otherwise Integrated solution CNVi will be enabled Disable Integrated disables Integrated Solution NOTE When CNVi is present the GPIO pins that are used for radio...

Page 75: ...er of Cores and E cores are looked at together When both are 0 0 Pcode will enable all cores Hyper Threading Disabled Enabled Default Enabled for Windows XP and Linux OS optimized for Hyper Threading...

Page 76: ...VCO 6000 ADL l User s Manual 3 3 2 1 Efficient core Information 3 3 2 2 Performance core Information 76 Chapter 3 BIOS Setup...

Page 77: ...OS Features Disabled Enabled Default When disabled AMT BIOS Features are no longer supported and user is no longer able to access MEBx Setup Note This option does not disable Manageability Features in...

Page 78: ...er s Enabled Default Disabled Enable Disable SATA Device SATA Port Disabled Enabled Default Enable Disable SATA Port Hot Plug Disabled Enabled Default Designates this port as Hot Pluggable SATA Device...

Page 79: ...FI RAID Configuration How to set the UEFI RAID 1 When set to Enable VMD controller please save change reset system 2 After reboot the system please into BIOS utility and then will see Intel R Rapid St...

Page 80: ...6000 ADL l User s Manual 3 Into Intel R Rapid Storage Technology and start create RAID volume 4 Start Create the RAID Select Disk that you want to do the RAID Select x No Select 80 Chapter 3 BIOS Set...

Page 81: ...Disabled Default Enable Disable BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be available Pending operation None Default TPM Clear S...

Page 82: ...ation Disabled Enabled Default Enables or Disables System ability to Hibernate OS S4 Sleep State This option may not be effective with some operating systems ACPI Sleep State Suspend Disabled S3 Suspe...

Page 83: ...ult Minute Mode Select Second Mode or Minute Mode Watch Dog Timer Time out Value 20 255 Second Default 1 255 Minute Watch Dog Timer Time out Value Item Description Serial Port 1 Configuration Set Para...

Page 84: ...h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 This item allows you to change the address IRQ settings of t...

Page 85: ...h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 This item allows you to change the address IRQ settings of t...

Page 86: ...h IRQ 7 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F0h IRQ 3 4 5 6 7 9 10 11 12 IO 2E0h IRQ 3 4 5 6 7 9 10 11 12 This item allows you to change the address IRQ settings of t...

Page 87: ...h IRQ 7 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F0h IRQ 3 4 5 6 7 9 10 11 12 IO 2E0h IRQ 3 4 5 6 7 9 10 11 12 This item allows you to change the address IRQ settings of t...

Page 88: ...h IRQ 7 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F0h IRQ 3 4 5 6 7 9 10 11 12 IO 2E0h IRQ 3 4 5 6 7 9 10 11 12 This item allows you to change the address IRQ settings of t...

Page 89: ...3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F0h IRQ 3 4 5 6 7 9 10 11 12 IO 2E0h IRQ 3 4 5 6 7 9 10 11 12 This item allows you to change the address IRQ settings of the specified serial port Device Type Select...

Page 90: ...Setup 3 3 9 Hardware Monitor These items display the current status of all monitored hardware devices components such as voltages and temperatures Item Options Description Smart Fan Function Disabled...

Page 91: ...t Fan Mode Configuration Item Options Description FanSIO SmartFan Control Manual Mode Auto Duty Cycle Mode Default Smart Fan Mode Select Temperature 1 4 1 100 Auto fan speed control Temperature 1 100...

Page 92: ...y read settings from IGN module Write IGN BIOS will overwrite settings in IGN module Power On Delay 10 Sec Default 20 Sec 30 Sec 40 Sec 50 Sec 1 Min Manual Mode Power On Delay Select Manual Mode 10 Se...

Page 93: ...n sec specified Select DynamicTime System will wake on the current time Increase minute s Bypass BIOS will not control RTC wake function during system shutdown Wake up day 0 Default Date of month Alar...

Page 94: ...User s Manual 3 3 12 Serial Port Console Redirection 94 Chapter 3 BIOS Setup Item Options Description Console Redirection Disabled Default Enabled These items allows you to enable or disable COM1 cons...

Page 95: ...XHCI ownership change should be claimed by XHCI driver USB Mass Storage Driver Support Enabled Default Disabled Enable Disable USB Mass Storage Driver Support USB transfer time out 1 sec 5 sec 10 sec...

Page 96: ...pport If disabled IPv4 HTTP boot support will not be available IPv6 PXE Support Disabled Default Enabled Enable Disable IPv4 PXE boot support If disabled IPv6 PXE boot support will not be available IP...

Page 97: ...on ROM Immediate execute the trap right away postponed execute the trap during legacy boot Boot option filter UEFI and Legacy Legacy only UEFI only Default This item allows users to select which type...

Page 98: ...VCO 6000 ADL l User s Manual 3 3 16 NVMe Configuration 98 Chapter 3 BIOS Setup...

Page 99: ...set up some system features according to your preference 3 4 1 System Agent SA Configuration 99 Chapter 3 BIOS Setup Item Options Description Above 4GB MMIO BIOS assignment Enabled Disabled Default En...

Page 100: ...Setup Item Options Description Max TOLUD Dynamic Default 1GB 1 25GB 1 5 GB 1 75 GB 2 GB 2 25 GB 2 5 GB 2 75 GB 3 GB 3 25 GB 3 5 GB Maximum Value of TOLUD Dynamic assignment would adjust TOLUD automat...

Page 101: ...p options GTT Size 2MB 4MB 8MB Default Select the GTT Size Aperture Size 128MB 256MB Default 512MB 1024MB Select the Aperture Size Note Above 4GB MMIO BIOS assignment is automatically enabled when sel...

Page 102: ...VCO 6000 ADL l User s Manual VMD Configuration 102 Chapter 3 BIOS Setup Item Options Description Enable VMD controller Enabled Default Disabled Enable Disable to VMD controller...

Page 103: ...VCO 6000 ADL l User s Manual PCI Express Configuration 103 Chapter 3 BIOS Setup...

Page 104: ...4 Chapter 3 BIOS Setup Item Options Description PCI Express Root Port 1 3 Disabled Enabled Default Control the PCI Express Root Port ASPM Disabled Default L0s L1 L0sL1 Set the ASPM Level PCIe Speed Au...

Page 105: ...hapter 3 BIOS Setup Item Options Description Restore AC Power Loss Power On Power Off Default Lase State Specify what state to go to when power is re applied after a power failure G3 state M 2 B Key S...

Page 106: ...VCO 6000 ADL l User s Manual PCI Express Configuration 106 Chapter 3 BIOS Setup...

Page 107: ...ions Description PCI Express Root Port 1 3 5 6 7 8 9 Disabled Enabled Default Control the PCI Express Root Port ASPM Disabled Default L1 Auto Set the ASPM Level PCIe Speed Auto Default Gen1 Gen2 Gen3...

Page 108: ...udio Configuration 108 Chapter 3 BIOS Setup Item Options Description HD Audio Disabled Enabled Default Control Detection of the HD Audio device Disabled HDA will be unconditionally disabled Enabled HD...

Page 109: ...rity Security menu allow users to change administrator password and user password settings Administrator Password This item allows you to set Administrator Password User Password This item allows you...

Page 110: ...ature is Active if Secure Boot is Enabled Platform Key PK is enrolled and the System is in User mode The mode change requires platform reset Secure Boot Mode Standard Custom Default Secure Boot mode o...

Page 111: ...Manual 111 Chapter 3 BIOS Setup Item Options Description Factory Key Provision Disabled Default Enabled Install factory default Secure Boot keys after the platform reset and while the System is in Set...

Page 112: ...o wait for setup activation key 65535 0xFFFF means indefinite waiting Bootup NumLock State On Default Off Select the Keyboard NumLock state Quiet Boot Disabled Default Enabled Enables or disables Quie...

Page 113: ...item allows user to reset the system after saving the changes This item allows user to reset the system after saving the changes Discard Changes and Reset This item allows user to reset the system wit...

Page 114: ...VCO 6000 ADL l User s Manual 114 3 8 MEBx Chapter 3 BIOS Setup Item Options Description Intel R ME Password MEBx Login...

Page 115: ...Appendix WDT GPIO This appendix provides the sample codes of WDT Watch Dog Timer and GPIO General Purpose Input Output...

Page 116: ...s The configuration on the VCO 6000 ADL is described as below Psuedo Code IO Address 0xA16 is time value second IO Address 0xA15 is WDT enable and configuration Example Set 0xA16 0x03 0xA15 0x31 it wi...

Page 117: ...2 IO_DO4 IO_DO6 IO_DO8 to Low SmbusWrite Slave_ADDR GPO_ADDR 0x55 Read In1 In8 value Data SmbusReads Slave_ADDR GPI_ADDR Read In1 In8 value Appendix WDT GPIO PIN GPIO Default Configuration 18 XCOM 17...

Page 118: ...Copyright C T Solution Inc All Rights Reserved www candtsolution com...

Reviews: