1066 Pro
10
should be 3. If the value is 1 or 2, you need to contact our after-sales personnel to
deal with it. If it is 0, you need to check the power status according to the following.
✓
Check the power, temperature, network status and fan status
Click the Log in the menu as below.
Check the following fields in the right field:
•
NETFAIL (as shown in
②
) : records the time of disconnection from the ore pool (if it
has not been disconnected or never connected to the ore pool, this is all 0).In the
record, the odd term (items 1, 3, and 5) is the time of disconnection from the pool,
and the even term (items 2, 4, and 6) is the time of recovery from the pool. If only
the odd term has data and the even term is 0, it means that the connection with the
pool is disconnected and not recovered (usually because of the excessive traffic of
the pool server, the connection can be broken. If frequent occurrence occurs for a
long time, the other mining pool can be replaced).
•
SYSTEMSTATU: records the current working state, normally In Work (shown In
③
).Where Hash Board (as shown in
④
) is the number of working Hash boards,
which should be 3 for 1066 Pro. If it is 1 or 2, we need to contact the after-sales
service. If it is 0, you need to further check the state of the power supply.
•
Temp is the ambient temperature and cannot exceed 35
℃
•
TMax is the highest chip temperature, which cannot exceed 85
℃
.
•
TAvg is the average chip temperature.