background image

LP safety: 

(a)  Do not store a spare LP-gas cylinder under or near this appliance.

(b)  Never fill the cylinder beyond 80 percent full. 

(c)  If the information in “(a)” and “(b)” is not followed exactly, a fire causing death or serious 

      injury may occur.

(d)  Do not use this appliance under overhead combustible surfaces.

Minimum Clearances:

Bottom: Non-combustible Surface

Top: 80 inches

Sides: 36 inches

For Installation: on(or over)Non-combustible Floors Only

Max Input: 52,000 BTU (17. 0kW)

Max gas supply pressure: 250 PSI

This appliance shall be used only outdoors in a well-ventilated space and shall not be used in a building, garage or 

any other enclosed area. 

If this appliance is not in use, the gas must be turned off at the supply cylinder. 

Indoor storage of this appliance is permissible only if the cylinder is disconnected and removed from the appliance. 

Cylinders must be stored outdoors in a well ventilated area out of the reach of children. Disconnected cylinders 

must have threaded valve plugs tightly installed and must not be stored in a building, garage or any other enclosed 

area. 

The gas pressure regulator provided with this appliance must be used, and must be the same model as supplied 

with the unit. 

The cylinder supply system must be arranged for vapor withdrawal. 

Cylinders used with this unit must have a collar to protect the cylinder valve. To avoid tipping over the cylinder, the 

use of a LP-cylinder stabilizer is recommended when the appliance is in use. 

Please ensure that all adults and children who use or are near a unit in use are aware of the hazard of high surface 

temperature of the unit during use. They should use cautiously and stay away from a unit in use to avoid burns or 

clothing ignition.

Carefully supervise young children in the area where this appliance is placed. 

Clothing or other flammable materials should not be placed on or near the appliance. 

Any guard or other protective device removed for servicing the appliance must be replaced prior to operating the 

appliance. 

Installation and repair should be done by a qualified service person. The appliance should be inspected before use 

and at least inspected annually by a qualified service person. 

Frequent cleaning may be required as necessary. It is imperative that control compartment, burners and circulating 

air passage ways of the appliance be kept clean.

All LP cylinders to be used with this appliance must be:

- Constructed and marked in accordance with the specifications for LP-gas cylinders Standard, CAN/CSA B339, 

  Cylinders, Spheres and Tubes for the Transportation of Dangerous Goods.

- Provided with a listed overfilling prevention device.

- Provided with a cylinder connection device compatible with the connection for outdoor cooking appliances.

- The LP-gas cylinder used for this appliance must not have a capacity larger than 20 lb (9 kg): Approximately 

  18" (46 cm) high &12" (30 cm) diameter.

The use of an approved LP-gas cylinder stabilizer is recommended when using this appliance in order to prevent 

the LP-gas cylinder from tipping over.

2

www.camplux.com

Visit Us: Camplux.com

[email protected]

3330-A Marathon Ct Charleston, SC 29418

1(844) 538-7475

Summary of Contents for FP19MB

Page 1: ...Visit Us Camplux com support camplux com 3330 A Marathon Ct Charleston SC 29418 1 844 538 7475 Model FP19MB FP19ML FP19AL OUTDOOR PORTABLE FIRE PIT Instruction For Installation And Use...

Page 2: ...A LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can k...

Page 3: ...ensure that all adults and children who use or are near a unit in use are aware of the hazard of high surface temperature of the unit during use They should use cautiously and stay away from a unit in...

Page 4: ...tion opening s shall be provided at floor level of the enclosure and shall have a total free area of not less than 1 2 in2 lb 7 1 cm2 kg of stored fuel capacity If ventilation openings at floor level...

Page 5: ...ction hold the regulator in a straight line with the cylinder valve so as not to cross thread the connection 5 Leak test the connection See leak test Nipple With Flow Limiting Device Heat Sensitive Ha...

Page 6: ...ed or dirty wipe lightly with a damp cloth Do not use flammable or corrosive cleaning products on or near this unit Ensure that the gas hose is placed in an area where it is unlikely to be tripped ove...

Page 7: ...ltation Section 2 Manual Ignition Model FP19MB FP19ML Item KLD4004 1 Ensure that the valve dial of the unit is on the off position by pushing and turning clockwise until the dial stops Fig 3 2 Securel...

Page 8: ...r then open the valve on the appliance slowly by turning anticlockwise until the unit ignites Ensure that no part of your body clothing or any other combustible material are above burner before during...

Page 9: ...fire It is designed to use safely combustible propane only Do not connect to a remote gas supply Do not use this appliance if any part of it has been under water Immediately call a qualified service t...

Page 10: ...Visit Us Camplux com support camplux com 3330 A Marathon Ct Charleston SC 29418 1 844 538 7475...

Page 11: ...Visit Us Camplux com support camplux com 3330 A Marathon Ct Charleston SC 29418 1 844 538 7475 Mod le N FP19MB FP19ML FP19AL FOYER D EXT RIEUR PORTABLE Instruction pour l installation et l utilisation...

Page 12: ...le de GPL qui n est pas raccord e pour tre utilis e ne doit pas tre rang e proximit du foyer ou de tout autre appareil L appareil produit du monoxyde de carbone qui est sans odeur Utiliser cet apparei...

Page 13: ...tous les adultes et les enfants qui utilisent ou se trouvent proximit d un appareil en cours d utilisation sont conscients des risques li s la temp rature de surface lev e de l appareil en cours d ut...

Page 14: ...nt tre situ es au niveau du sol de l enceinte et doivent avoir une surface totale libre d au moins 7 1 cm2 kg 1 2 in2 lb de capacit de stockage du carburant Si les ouvertures de ventilation situ es au...

Page 15: ...ille et les robinets de l appareil sont arr t s 2 Placez la bouteille de GPL pleine sur le support de bague du r servoir 3 Centrez le mamelon dans le robinet de la bouteille et maintenez le en place 4...

Page 16: ...on humide N utilisez pas de produits de nettoyage inflammables ou corrosifs sur ou proximit de cet appareil Assurez vous que le tuyau de gaz est plac dans une zone o il est peu probable qu il tr buche...

Page 17: ...au repos pendant au moins une heure pour permettre l exc s de gaz de s chapper Au bout d une heure d branchez le tuyau et apportez le un technicien agr en propane pour consultation Section 2 Allumage...

Page 18: ...squ ce que l appareil s allume Assurez vous qu aucune partie de votre corps de vos v tements ou de tout autre mat riau combustible ne se trouve au dessus du br leur avant pendant et apr s l allumage F...

Page 19: ...acez aucun objet autre que des roches fournies l int rieur du br leur du foyer N ajoutez pas de bois ou d autres mat riaux au feu Il est con u pour utiliser uniquement du propane combustible en toute...

Page 20: ...Visit Us Camplux com support camplux com 3330 A Marathon Ct Charleston SC 29418 1 844 538 7475...

Reviews: