Order codes 

 

Description 

      

Order 

code 

Standard Tissue Bath Cooler (complete) 

 

7600 

Autoclavable Tissue Bath Cooler (complete)  

7600S 

Control 

Unit 

     7600/1 

Standard Tissue bath assembly 

 

 

7600/2 

Autoclavable Tissue bath assembly   

 

7600/3 

Autoclavable tissue bath only  

 

 

7600/4 

Heat 

transfer 

Paste 

    765-HTP 

 
Specification 

 
Display 

Resolution 

    0.1 

ºC 

Temperature 

Accuracy    +/- 

ºC 

Temperature 

Range 

 

    +8ºC 

to 

0ºC 

(Note that the actual temperatures achievable will be dependent upon the solutions 
used and local temperature conditions)   

Voltage requirements   

 

 

 

230V 50Hz or 115V 60Hz  

Power 

Rating 

     60W 

Inlet 

Fuse 

Rating 

    T1.25A 

 
For further information contact: 
CAMPDEN INSTRUMENTS, 
PO BOX 8148 
LOUGHBOROUGH, 
LEICESTERSHIRE 
LE12 7XT. 
UK. 
 
Telephone: 

(+44) 0150 981 4790 

Fax: 

 

(+44) 0150 981 7701 

[email protected]
www.campdeninstruments.com

 

 

Summary of Contents for 7600 Series

Page 1: ...Campden Instruments UK PO Box 8148 Loughborough Leicestershire LE12 7TJ Tel 44 01509 817700 Fax 44 01509 81770 Campden Instruments USA at Lafayette Instrument Co PO Box 5729 Lafayette Indiana 47903 T...

Page 2: ...en Instruments Limited No part of this manual may be reproduced in any form or by any means including photocopying or storing in any medium by electronic means without the written permission of the co...

Page 3: ...l be able to advise on this matter 1 1 Overview The 7600 Tissue Bath Cooler Unit is intended for use with the Campden Instruments Range of vibrating microtomes Unfixed brain slices sectioned at 4o C g...

Page 4: ...rature to within 0 5 C of the temperature set point There will however be a small variation in temperature vertically through the bath Experience will show the best temperature to be set for any given...

Page 5: ...t moulding See Figure 2 On Off switch Mains socket Voltage selector fuse drawer Figure 2 Mains inlet voltage selector example shown is set to 110 120V The inlet moulding accepts a standard IEC socket...

Page 6: ...tle to between 1 C and 2 C above that of the measured temperature depending on conditions For the users convenience the set temperature and actual temperature displayed are offset by 1 C i e A display...

Page 7: ...of 19000ppm A c s f has a much higher concentration This concentration will increase due to evaporation and the passive oxide layer will break down For this reason it is essential that the bath and h...

Page 8: ...ation Display Resolution 0 1 C Temperature Accuracy 1 C Temperature Range 8 C to 0 C Note that the actual temperatures achievable will be dependent upon the solutions used and local temperature condit...

Reviews: