Appendix D. RAWS-7 Data Format
D-7
16: End (P95)
; Correct Fuel Moisture
17: Polynomial (P55)
1: 1
Reps
2: 28
X Loc [ FuelM ]
3: 28
F(X) Loc [ FuelM ]
4: -220.14 C0
5: 365.89 C1
6: -114.96 C2
7: 0.0
C3
8: 0.0
C4
9: 0.0
C5
; Convert Air Temp to degrees F
18: Z=X*F (P37)
1: 3
X Loc [ AirTemp ]
2: 1.8
F
3: 3
Z Loc [ AirTemp ]
19: Z=X+F (P34)
1: 3
X Loc [ AirTemp ]
2: 32.0
F
3: 3
Z Loc [ AirTemp ]
; Eliminate RH values greater than 100
20: If (X<=>F) (P89)
1: 4
X Loc [ RH ]
2: 3
>=
3: 100
F
4: 30
Then
Do
21: Z=F (P30)
1: 100
F
2: 0
Exponent
of
10
3: 4
Z Loc [ RH ]
22: End (P95)
; correct zero wind speed offset.
23: If (X<=>F) (P89)
1: 5
X Loc [ Wspd ]
2: 4
<
3: 0.4001 F
4: 30
Then
Do
24: Z=F (P30)
1: 0
F
2: 0
Exponent
of
10
3: 5
Z Loc [ Wspd ]
25: End (P95)