TB4, TB4MM, CS700, and CS700H Tipping Bucket Rain Gages
3
3.
In the
Available Sensors and Devices
box, type TB4 or CS700. You can
also locate the sensor in the
Sensors
|
Meteorological | Precipitation
folder. Double-click
TB4/TB4MM
or
CS700 Rain Gauge
. The units
defaults to millimeters, which can be changed by clicking the
Rain
box
and selecting one of the other options. The default rainfall per tip value of
0.01 inches should be used if the sensor is a TB4 or CS700 purchased at
Campbell Scientific (U.S. office). Select 0.2 mm if the sensor is a TB4MM
purchased at Campbell Scientific (U.S. office) or a TB4 or CS700
purchase at Campbell Scientific Canada.
4.
Click on the
Wiring
tab to see how the sensor is to be wired to the data
logger. Click
OK
after wiring the sensor.
5.
Repeat steps three and four for other sensors. Click
Next
.