background image

1

SVP48 Surge Voltage Protector

1.  Overview

The SVP48 provides transient protection for up to 22 conductors.  Typical
usage is to place the SVP48 in line between sensors and a Campbell Scientific
datalogger to supplement the datalogger’s built in surge protection.

The SVP48 is designed to mount on Campbell Scientific's standard enclosure
back plates with 1 inch centered, pre-punched square accessory mounting holes.

The SVP48 consists of one or more surge protectors mounted on a DIN rail
bracket.  A single end plate is used to cover the last surge protector.

1.1  Physical Dimensions

Length: 6.6 inches

Width:

2.6 inches

Height: 2.72 inches

The two mounting holes in the DIN rail are spaced 6 inches apart center to
center.

1.2  Specifications

Surge protection is provided by gas filled arrestors that trigger at 110 VAC or
156 VDC.  Each surge protector protects one conductor and provides a terminal
for shield wires.

Reviews: