Section 5. Data Retrieval
5-2
ships with AC adapter but, in addition, offers the option of a remote power /
field cable (item number 14020) to facilitate connection to datalogger power
for the SC532A and the Storage Module where 120 VAC is not available.
5.1.2 Via Datalogger
The Storage Module is linked to the CR500/510, CR10/10X or CR23X by the
SC12 cable. The computer connection is via an SC32A (Figure 5-2), SC929 or
SC532(A)/RAD modem interface. For this configuration with the CR23X,
connect all devices to the 9 pin CS I/O port. Select the “ Via Datalogger”
option in SMS and select the appropriate datalogger and baud rate.
Please note that communication in this mode is limited to a maximum speed of
9600 baud (19200 on the CR23X), which can make the transfer of large
volumes of data a lengthy process, compared to direct connection to a PC
where baud rates up to 115200 are supported.
The SC32A internal SDM blocking jumper should be in place. Without the
jumper in place (and sometimes with the SC929/RAD), Windows may report a
“ framing error” after correctly collecting data with SMS.
PC
SM4M/16M
Data-
logger
FIGURE 5-2. Communication Via the CR500/510, CR10/10X or CR23X
Communication between a PC and Storage Module can also take place via the
CR23X when the computer RS232 is connected to the CR23X RS232 and the
Storage Module is connected to the CS I/O port (Figure 5-3). This
configuration allows baud rates of 19200 and 38400.
SM4M/16M
CR23X
PC
RS232
CS I/O
9-Pin
Cable
SC12
9-Pin
Cable
FIGURE 5-3. Communication Via the CR23X
Summary of Contents for SM16M
Page 6: ...SM4M 16M Flash Storage Module Table of Contents iv This is a blank page...
Page 14: ...Section 1 SM4M SM16M Storage Module Overview 1 8 This is a blank page...
Page 22: ...Section 3 The Printer Enable Method of Data Storage 3 4 This is a blank page...
Page 40: ...This is a blank page...
Page 42: ...This is a blank page...
Page 44: ...This is a blank page...
Page 45: ...This is a blank page...