CRBasic Example 1: Checking the operating system version and signature
' --------------------------------------------------------------------------
' Simple OS version and OS sig check for the SDM-SIO2R
' --------------------------------------------------------------------------
'Variables and constants for the version number and signature checking
Public
Ver_Value
As String
* 25
'Holds version as text string
Public
Sig_Value
As String
* 4
'Holds SIG of OS as four byte HEX string
Public
Sig_Value_Dec
'Holds sig as a decimal number
'Change this address to match the SDM-SIO2R SDM address.
Const
SDM_Address=0
Dim
Src
As String
* 1
Const
cmd = 5
'constant cmd = 0..7
Const
bytes_out = 1
'constant number of bytes out
Const
bytes_val = 1
'constant bytes per value (1,2,4)
Const
big_endian = 1
'constant 1 (big endian) or 0 (little endian)
Const
delay_usec = -0
'constant delay between outgoing bytes (negative means
'delay also for incoming bytes)
Const
Ver_values_in = 20
'constant number of values to receive
Const
Sig_values_in = 4
'constant number of values to receive
SequentialMode
BeginProg
SDMSpeed
(30)
'Fix the speed
Ver_Value =
""
Sig_Value =
""
Scan
(1,Sec,0,0)
'Use the generic SDM instruction to get extra info from the SDM-SIO2R
'Ask for the operating system version
Src =
CHR
(1)
SDMGeneric
(Ver_Value,SDM_Address,cmd,bytes_out,Src,Ver_values_in,bytes_val, _
big_endian,delay_usec)
'Read signature
Src =
CHR
(2)
SDMGeneric
(Sig_Value,SDM_Address,cmd,bytes_out,Src,Sig_values_in, _
bytes_val,big_endian,delay_usec)
Sig_Value_Dec =
HexToDec
(Sig_Value)
'Convert sig to decimal too.
Next Scan
EndProg
SDM-SIO2R Serial Input/Output Module with Switched Sensor Power