TABLE 10-1. Function of
NumRecs
,
Interval
, and
Units
Parameters
NumRecs/
Time Into
Interval
(d)
Entry
Interval
(e)
Entry
Units
(f)
Entry
Function
0
0
N/A
(compiler
ignores)
When the SC115 is connected
to the data logger, the data
logger automatically sends to
the SC115 only the data
collected after the SC115 was
last connected. The data
logger will not send additional
data if the SC115 remains
connected to the data logger.
0
–1
N/A
(compiler
ignores)
When the SC115 is connected
to the data logger, the data
logger automatically sends to
the SC115 all of the data
contained in the data logger’s
memory. The data logger will
not send additional data if the
SC115 remains connected to
the data logger.
number of
data
records
(value > 0)
0
N/A
(compiler
ignores)
The data logger sends the
specified number of data
records to the SC115 when
the data records become
available. For example, if the
NumRecs
parameter is set to
20
and
Interval
is set to
0
, the
data logger will write twenty
records to the SC115 when
twenty records become
available.
time into
interval
(value ≥ 0)
interval
(value > 0)
mSec
,
uSec
,
Sec
,
Min
,
Hr
,
or
Day
The data logger sends data to
the SC115 at the specified
interval. For example, when
the
NumRecs/Time Into
Interval
parameter is set to
0
,
the
Interval
parameter is set to
60
and the
Units
parameter is
set to
Min
, the data logger will
write data to the SC115 every
60 minutes.
The following sections explain each
TableFile()
parameter in detail.