SC115 CS I/O 2G Flash Memory Drive with USB Interface
3
5.1 Memory Drive Function
As a memory drive, when the SC115 is attached to the CS I/O port of a data
logger, the LED (Light Emitting Diode) first flickers as the SC115 and data
logger negotiate communications. The data logger determines if the
TableFile()
instruction is set to write to an SC115. The LED flickers as the
data logger copies data files to the SC115. The LED stops flickering when data
transfer is complete, and the SC115 can safely be disconnected.
As a memory drive, when the SC115 is attached to a computer, the LED first
lights solidly as it communicates with the computer to obtain a unique address.
Once negotiations are finished, the LED extinguishes and the SC115 appears as
a removable drive in Windows
®
Explorer. Data files on the SC115 can be
copied or moved to other drives. Files, such as CRBasic program files or
operating system (OS) files, can be copied or moved from computer drives to
the SC115.
5.2 Communications Interface Function
As a communication device, the SC115 provides pass-through
communications.
5.3 Features
•
Portable 2-GB memory drive
•
Shuttles data, OS, and program files or remains connected to data logger to
augment memory
•
Can be used as a CS I/O to USB communications interface
•
Mean time between failure (MTBF): >1,000,000 hrs
•
Sealed, over-moulded case. No serviceable parts.
6. Specifications
Compatibility
Data loggers:
GRANITE series, CR9000X, CR6, CR3000,
CR1000X, CR800 series, CR5000, CR1000
A data logger can have only one SC115 connected.
Temperature
Operating:
–25 to 50 °C
Power requirement
Source:
12 Vdc from data logger CS I/O port,
or 5 Vdc through computer USB port
Load
Idle:
200 µA
Active:
35 mA
Memory
Capacity:
2 GB
Media:
Flash
NOTE