![Campbell RainVUE SDI-12 Series Product Manual Download Page 21](http://html1.mh-extra.com/html/campbell/rainvue-sdi-12-series/rainvue-sdi-12-series_product-manual_3912376021.webp)
12. Mate the extension cable connector to the cable connector. Only hand tighten the
connectors.
7.3 Wiring
Connect the wires in the order shown in the following table.
Table
7-1:
Wire
colo
ur
,
function,
and
data
logger
connection
Wire
colo
u
r
Wire function
Data logger connection
White
SDI-12 signal
C, SDI-12, or U configured for SDI-12
1
Clear
Shield
⏚
(analog
ue
ground)
Brown
Power
12V
Black
Power ground
G
1
U and C terminals are automatically configured by the measurement instruction.
If multiple SDI-12 sensors are connected to a data logger, Campbell Scientific recommends using
separate terminals when possible. However, multiple SDI-12 sensors can connect to the same
data logger control or U terminal. Each must have a unique SDI-12 address. Valid addresses are 0
through 9, a through z, and A through Z.
For the CR6 and CR1000X data loggers, triggering conflicts may occur when a companion
terminal is used for a triggering instruction such as
TimerInput()
,
PulseCount()
, or
WaitDigTrig()
. For example, if the RainVUE-series is connected to C3 on a CR1000X, C4
cannot be used in the
TimerInput()
,
PulseCount()
, or
WaitDigTrig()
instructions.
7.4 Data logger programming
Short Cut
is the best source for up-to-date programming code for Campbell Scientific data
loggers. If your data acquisition requirements are simple, you can probably create and maintain a
data logger program exclusively with
Short Cut
. If your data acquisition needs are more complex,
the files that
Short Cut
creates are a great source for programming code to start a new program
or add to an existing custom program.
NOTE:
Short Cut
cannot edit programs after they are imported and edited in
CRBasic Editor
.
A
Short Cut
tutorial is available in
(p. 2). If you wish to import
Short Cut
code into
CRBasic Editor
to create or add to a customized program, follow the procedure in
Short Cut code into CRBasic Editor
(p. 26). Programming basics for CRBasic data loggers are
RainVUE-Series SDI-12 Precipitation Sensors
11