PS150/CH150 12 V Charging Regulators
9
FIGURE 3-8. Wiring harness plugged into battery connector
3.3 Hook Up Power to Data Logger
Both the PS150 and the CH150 come with a 1-foot black wire attached to one
of the
G
terminal blocks and a 1-foot red wire attached to one of the
12V
terminal blocks. Attach the red wire from the power supply to the data logger
2-Pin Screw Terminal Plug Connector marked
12V
. Attach the black wire from
the power supply to the data logger 2-Pin Screw Terminal Plug Connector
marked
G
.
3.4 Turn On the Charging Source
Turn on the power going to the charging source or uncover the solar panel. The
green
Charge
LED will flash approximately once a second if all incoming
connections are correct and there is an adequate charging voltage present.
3.5 Turn On Power to the Data Logger
Toggle the switch on the PS150/CH150 supply to
On
. Verify voltage to the
data logger with a volt meter, display, or connect to the data logger with a
laptop to make sure the data logger is running correctly.
3.6 LED Indicator
The green
Charge
LED will flash approximately once a second if all incoming
connections are correct and there is an adequate charging voltage present.