NL241 Wireless Network Link Interface
27
•
On the
NL241
tab:
o
Set
Bridge Mode
to
disable
.
•
On the
RS-232
tab:
o
Set
Configuration
to
TCP Serial Server
.
o
Set
Baud Rate
to baud rate of attached device.
o
Make note of the
Serial Service Port
. (The default RS-232
Serial
Service Port
is
6784
. Typically, it is not necessary to change this
entry from its default.)
CS I/O Serial Server
Connect to the NL241 in
DevConfig
(p. 17)
).
•
On the
NL241
tab:
o
Set
Bridge Mode
to
disable
.
•
On the
CS I/O
tab:
o
Set
Configuration
to
TCP Serial Server
.
o
Set
SDC address
. (Note that if multiple peripherals are connected to a
datalogger
CS I/O
port, each must have a unique SDC address.)
o
Make note of the
Serial Service Port
. (The default CS I/O
Serial
Service Port
is
6783
. Typically, it is not necessary to change this
entry from its default.)
8.2.3.3 LoggerNet Setup
The next step is to run
LoggerNet
and configure it to connect to the datalogger
via the Wi-Fi port. (See example in FIGURE
1.
In the
LoggerNet Setup
Screen
, click
Add Root
and choose
IPPort
. Input
the NL241 IP address and port number. The IP address and port number
are input on the same line separated by a colon.
2.
Add a PakBus® Port.
3.
Add the datalogger and input the PakBus® address of the datalogger.
4.
Press
Apply
to save the changes.
5.
You can verify your settings are correct by selecting the datalogger in the
Network Map
, clicking the
Clock
tab, and clicking
Check Clocks
. If
your settings are correct, you should see the current clock of your server
and datalogger.