Appendix C. EasyFlux
®
DL CR6KH20
C-25
TABLE C-21. Data Fields in the Flux_CSFormat Data Output Table
Data Field Name
Units
Description
Data Field
Included
LE
W·m
-2
Final corrected latent heat flux
Always
LE_QC
grade
Overall quality grade for LE
following Foken et al. 2012
Always
LE_samples
count
The total number of time series
samples used in calculation of LE
Always
H
W·m
-2
Final corrected sensible heat flux
derived from sonic sensible heat flux
Always
H_QC
grade
Overall quality grade for Hs
following Foken et al. 2012
Always
H_samples
count
The total number of time series
samples used in calculation of H
Always
H_FW
W·m
-2
Final corrected sensible heat flux
derived from fine-wire thermocouple
measurements
If FW05,
FW1, or FW3
is used
H_FW_samples
count
The total number of time series
samples used in calculation of H_FW
If FW05,
FW1, or FW3
is used
NETRAD
W·m
-2
Average net radiation (corrected for
wind)
If NR-LITE2,
SN500SS,
NR01, or
CNR4 used
G
W·m
-2
Heat flux at the ground surface
If energy
balance
sensors are
used
SG
W·m
-2
The change in heat storage in the soil
above the soil heat flux plates during
the averaging interval
If energy
balance
sensors used
energy_closure
fraction
The ratio of sensible and latent heat
fluxes to surface heat flux plus net
radiation
If energy
balance
sensors are
used
poor_enrg_clsur
none
If
TRUE
, despite favorable
meteorological conditions (adequate
turbulence and no rainfall), energy
closure is poor. Check instruments.
If energy
balance
sensors and
TE525 used
Bowen_ratio
fraction
The ratio of final sensible heat flux
over final latent heat flux
Always
TAU
kg·m
-1
·s
-2
Final corrected momentum flux
Always
TAU_QC
grade
Overall quality grade for tau
following Foken et al. 2012
Always
USTAR
m·s
-1
Friction velocity after coordinate
rotations and frequency corrections
Always