Appendix Title
2
Though this manual focuses on use of the Intelimax modem kit with Telstra’s
NextG service, the Intelimax is compatible with all 3G and GSM frequency
bands including those used by Optus, Vodafone and their resellers.
Coverage maps are available from the service providers. Please note however
that even though an area is shown as covered on the map, it is important to
check the signal strength on site. It is always possible that the location has poor
coverage due to interference or other technical reasons.
When installing outside of Australia, contact the local telecommunications
provider to source the appropriate SIM card and determine any additional
requirements for operating in your area.
As with any network based on radio technology, some local conditions may
prevent or interfere with mobile phone reception within coverage areas. Such
conditions may include concrete buildings, lift wells, below ground basements,
tunnels, mountains and road cuttings.
When in doubt of signal levels on site, make sure to check signal strength
before selecting a site and use an appropriate antenna to prevent costly future
visits to correct communications problems caused by poor signal reception.
4.
Specifications
Operating Temperature: -20°C to 65°C
Storage Temperature: -40°C to 85°C
Supply Voltage: 6V – 32V DC (Reverse Polarity Protected)
Power Consumption (12V)*:
Active Mode = 150mA
Dormant Mode = 50mA
Sleep Mode = 30mA
* dependant on RF conditions
Antenna: FME male (50
Ω
)
Data Interfaces:
RS232 and Power via RJ45
USB (mini B) for PC interface
Reset Switch for Hardware Reset
Dimensions (mm): 75 x 55 x 26
Weight: 95g