CSAT3 Three Dimensional Sonic Anemometer
35
24: Z=X (P31)
1: 5
X Loc [ diag ]
2: 30
Z Loc [ diag_work ]
25: If (X<=>F) (P89)
1: 30
X
Loc
[
diag_work
]
2: 2
<>
3: 61440 F
4: 30
Then
Do
26: If (X<=>F) (P89)
1: 30
X
Loc
[
diag_work
]
2: 1
=
3: 61503 F
4: 30
Then
Do
;Set the F03F (no data available) flag.
;
27: Z=F (P30)
1: 1
F
2: 0
Exponent
of
10
3: 26
Z Loc [ F03F_f ]
28: Else (P94)
;Set the delta temp (del_T_f), tracking (track_f), amplitude high
;amp_h_f), or amplitude low (amp_l_f) flag high if the CSAT3 is
;reporting those flags as set.
;
29: Beginning of Loop (P87)
1: 0
Delay
2: 4
Loop
Count
30: If (X<=>Y) (P88)
1: 30
X
Loc
[
diag_work
]
2: 3
>=
3: 31 --
Y Loc [ _8000h ]
4: 30
Then
Do
31: Z=F (P30)
1: 1
F
2: 0
Exponent
of
10
3: 22 --
Z Loc [ del_T_f ]
32: Z=X-Y (P35)
1: 30
X
Loc
[
diag_work
]
2: 31 --
Y Loc [ _8000h ]
3: 30
Z Loc [ diag_work ]
33: End (P95)
34: End (P95)
35: End (P95)