CS120A and CS125 Visibility and Present Weather Sensors
50
Menu 1: The message output menu
CS125 MESSAGE - MENU 1
ID 0
S/N 1006
(1) Set message format: FULL SYNOP
(2) Toggle units: METRES
(3) Toggle polled or continuous mode: CONTINUOUS
(4) Set continuous mode message-interval: 60 second(s)
(5) Toggle output averaging period: 1 minute(s)
(6) Sampling interval: 1 second(s)
(7) Configure custom message format
(6) Toggle special cal mode
(9) Refresh
(0) Return to main menu
Toggling special cal mode turns the TMOR output ON or OFF.
While in the message output menu, typing ‘1’ allows the message format to be
(p. 34)
). The following lists options.
Typing the appropriate number sets the required message format. The messages
are described in more detail in Section
Message Formats: A breakdown of
the different default outputs of the sensor – Basic/Partial/Full
(p. 24)
.
Note that the CS120A Visibility Sensor can only output messages 0-2 and a
limited custom message.
CS125 MESSAGE - SUB 3
Set the message output format. Current format is:
FULL SYNOP
- Basic = 0
- Partial = 1
- Full = 2
- Basic SYNOP = 3
- Partial SYNOP = 4
- Full SYNOP = 5
- Basic METAR = 6
- Partial METAR = 7
- Full METAR = 8
- Generic Basic SYNOP = 9
- Generic Partial SYNOP = 10
- Generic Full SYNOP = 11
- Custom output = 12
->
NOTE