![background image](http://html1.mh-extra.com/html/campbell/cr300-series/cr300-series_operators-manual_3055705023.webp)
CR300-Series Datalogger
13
Add measurements to the table by
selecting them under
Selected
Sensors
and then clicking on an
output processing option in the
center column of buttons.
Click
Finish
to compile the
program. Give the program a name.
A summary screen will appear
showing the compiler results. Any
errors during compiling will be
displayed.
If
LoggerNet
,
PC400
, or
PC200W
is
running on your PC, and the PC-to-
datalogger connection is active, you
can choose to send the program. See
(p.
, for setting up an active PC-to-
datalogger connection with
datalogger support software.
Select
BattV
under
Selected Sensors
and then click
Average
. Repeat this procedure for
PTemp_C
and
Temp_C
.
Give the program the name
MyTemperature
. Save it in the default
C:\CampbellSci\SCWin
folder. Do not send the
program at this time.
Click
No
. Do not send the program here. You will do this in Section
(p. 14)