background image

CPEC200

  

Closed Path  

Eddy Covariance System  

 

Quick Deploy Guide   

 

 

 

 

 

 

 

 

 

 

February 2016

 

 

 

 

 

 

 

Summary of Contents for CPEC200

Page 1: ...CPEC200 Closed Path Eddy Covariance System Quick Deploy Guide February 2016 ...

Page 2: ...1 Setup tripod and mount enclosures EC100 Enclosure CPEC200 Enclosure EC100 Enclosure Pump Module CPEC200 Enclosure Pump Module Optional Scrub Module Leg Mount Mixed Mast and Leg Mount ...

Page 3: ...2 Ground tripod and enclosures Ground Lug Grounding Rod ...

Page 4: ...3 Setup tripod or mast with CM20X Crossarm Crossarm To Pole Bracket CM20X Crossarm ...

Page 5: ...4 Mount the EC155 bypass tube EC155 bypass tube Mounting clip ...

Page 6: ...5 Mount gas analyzer and sonic anemometer EC155 Gas Analyzer CM20X Crossarm EC155 Boom Adapter Mounting Platform CSAT3A Sonic Anemometer Head Leveling Bubble ...

Page 7: ...6 Connect EC155 and CSAT3A to EC100 Electronics EC155 Analyzer Cable EC155 Sample Cell Cable CSAT3A Cable ...

Page 8: ...7 Connect system plumbing Zero Air Tubing Analyzer Tubing Pump Tubing Pump Module Cable CO2 Span Gas Tubing ...

Page 9: ...8 Connect system wiring and insert compact flash CF card EC100 Power and SDM Cables System Power Cable ensure 12 Vdc power supply is off Insert CF Card ...

Page 10: ...Power Cable to EC100 EC100 SDM Cable Power Cable to 12Vdc Power Supply off SDM Cable to EC100 EC100 Power Cable ...

Page 11: ...2 Vdc power supply and use the datalogger keyboard display to set settings and initiate zero span checks 9 1 Press Esc to activate the display Press Enter to display the System Control Menu 9 2 Select Configure System ...

Page 12: ...9 3 Select SONIC_AZIMU 9 4 Enter the CSAT3A sonic head azimuth ...

Page 13: ...9 5 If the CPEC does not have a valve module skip to 9 10 Otherwise select Zero Span Config 9 6 Select CO2_SPAN_PPM ...

Page 14: ...PPM to match the CO2 concentration of the CO2 span gas tank 9 8 Select CHECK_ZERO SET_ZERO CHECK_SPAN1 SET_SPAN1 in sequence Leave CHECK_SPAN2 CHECK_SPAN3 and CHECK_SPAN4 as FALSE unless the 6 valve module is being used ...

Page 15: ...9 9 For each value selected on the previous screen change the setting from False to True for auto zero span 9 10 Press ESC to exit ...

Page 16: ...Please visit www campbellsci com to obtain contact information for your local US or International representative ...