background image

PS100 and CH100 Power Supply and 
Charging Regulators, A100 Null Modem 
Adapter, and A105 Additional 12 V 
Terminals Adapter 

1.  General Description 

The PS100 is a 12-volt power supply that includes a charging regulator and a  
7 amp hour battery.  The CH100 is a charging regulator that is used with a 
Campbell Scientific battery pack such as the BP12 or BP24 or with a user-
supplied battery.  Charging power is typically supplied by an AC transformer 
or an unregulated solar panel.   

The PS100 and CH100 each have one adapter connector that will allow 
connecting one of the following adapters. 

The A100 Null Modem Adapter has two 9-pin connectors that provide a null 
modem for use in a site, without a datalogger.  The A100 connects and powers 
two Campbell Scientific peripherals that would normally be connected to a 
datalogger.  These peripherals are typically modems linking different 
communications technologies; e.g., telephone to radio. 

The A105 Additional 12 V Terminals Adapter may be used to provide 
additional 12 V and ground terminals where the power supply is used to power 
several devices. 

To prevent people from getting burned, an ABS plastic cover 
[CSI #18688] sits on the heatsink of a PS100 or CH100.  The 
cover is fastened to the heatsink via a #4-40 x .250 Pan Phillips 
screw [#395].  The cover must be removed to attach an A100 or 
A105 adapter.  Some early models of the PS100 and CH100 did 
not include the cover and do not have a place to attach it. 

NOTE 

2.  Specifications 

Input Voltage (CHG terminals)

 

15 to 28 VDC or 18 VAC RMS

 

 

Battery Connections 

 

Charging Output Voltage: 

Temperature compensated float 
charge for 12 V Battery 

Temperature Compensation Range: 

-40 to +60ºC 

Charging Current Limit: 

1.2 Amps typical 

 

 

Summary of Contents for CH100

Page 1: ...and CH100 Power Supply and Charging Regulators A100 Null Modem Adapter and A105 Additional 12 V Terminals Adapter Revision 4 09 C o p y r i g h t 2 0 0 0 2 0 0 9 C a m p b e l l S c i e n t i f i c I...

Page 2: ...US and International customers residing in countries served by Campbell Scientific Inc directly Affiliate companies handle repairs for customers within their territories Please visit www campbellsci...

Page 3: ...Use the Adobe Acrobat bookmarks tab for links to specific sections 1 General Description 1 2 Specifications 1 3 Wiring 2 4 A100 Null Modem Adapter 4 5 A105 12V Terminal Expansion Adapter 5 Figures 1 W...

Page 4: ......

Page 5: ...tific peripherals that would normally be connected to a datalogger These peripherals are typically modems linking different communications technologies e g telephone to radio The A105 Additional 12 V...

Page 6: ...RMS Protection automatic reset 85 C thermal reset breaker UL Approval UL 1950 AC Transformer CSI Model No 14014 Input Voltage 90 264 VAC 47 63 Hz Output Voltage 18 VDC Output Current max 1 3 Amps UL A...

Page 7: ...harged A battery must be attached for the charger to function correctly as a power supply CAUTION The leads from the transformer or solar panel are connected to the CHG terminals Polarity does not mat...

Page 8: ...tic 4 A100 Null Modem Adapter The A100 has two 9 pin CS I O ports with a null modem between them The ports are used to connect two 9 pin devices that would normally be connected to the CS I O port on...

Page 9: ...12 V 5 V 1 85 A Thermal Fuse FIGURE 3 Null Modem Connections 5 A105 12V Terminal Expansion Adapter The A105 adapter adds four 12 V terminals and four ground terminals to a CH100 or PS100 see Figure 4...

Page 10: ...PS100 and CH100 Power Supply and Charging Regulators 6...

Page 11: ......

Page 12: ...a Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Centro Caribe S A CSCC 300 N Cementerio Edificio Breller Santo Doming...

Reviews: