background image

Warranty and Assistance 

The

 

PS100 AND CH100 POWER SUPPLY AND CHARGING 

REGULATORS, A100 NULL MODEM ADAPTER, AND A105 
ADDITIONAL 12 V TERMINALS ADAPTER 

are warranted by 

CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and 
workmanship under normal use and service for twelve (12) months from date 
of shipment unless specified otherwise.  Batteries have no warranty.  
CAMPBELL SCIENTIFIC, INC.'s obligation under this warranty is limited to 
repairing or replacing (at CAMPBELL SCIENTIFIC, INC.'s option) defective 
products.  The customer shall assume all costs of removing, reinstalling, and 
shipping defective products to CAMPBELL SCIENTIFIC, INC.  CAMPBELL 
SCIENTIFIC, INC. will return such products by surface carrier prepaid.  This 
warranty shall not apply to any CAMPBELL SCIENTIFIC, INC. products 
which have been subjected to modification, misuse, neglect, accidents of 
nature, or shipping damage.  This warranty is in lieu of all other warranties, 
expressed or implied, including warranties of merchantability or fitness for a 
particular purpose.  CAMPBELL SCIENTIFIC, INC. is not liable for special, 
indirect, incidental, or consequential damages. 

Products may not be returned without prior authorization.  The following 
contact information is for US and International customers residing in countries 
served by Campbell Scientific, Inc. directly.  Affiliate companies handle 
repairs for customers within their territories.  Please visit 
www.campbellsci.com to determine which Campbell Scientific company 
serves your country.   

To obtain a Returned Materials Authorization (RMA), contact CAMPBELL 
SCIENTIFIC, INC., phone (435) 753-2342.  After an applications engineer 
determines the nature of the problem, an RMA number will be issued.  Please 
write this number clearly on the outside of the shipping container.  
CAMPBELL SCIENTIFIC's shipping address is: 

 

 

CAMPBELL SCIENTIFIC, INC. 

 RMA#_____ 
 

815 West 1800 North 

 

Logan, Utah 84321-1784 

 
For all returns, the customer must fill out a “Declaration of Hazardous Material 
and Decontamination” form and comply with the requirements specified in it.  
The form is available from our website at 

www.campbellsci.com/repair

.  A 

completed form must be either emailed to 

[email protected]

 or faxed 

to 435-750-9579.  Campbell Scientific will not process any returns until we 
receive this form.  If the form is not received within three days of product 
receipt or is incomplete, the product will be returned to the customer at the 
customer’s expense.  Campbell Scientific reserves the right to refuse service on 
products that were exposed to contaminants that may cause health or safety 
concerns for our employees. 

CAMPBELL SCIENTIFIC, INC. does not accept collect calls. 

Summary of Contents for CH100

Page 1: ...and CH100 Power Supply and Charging Regulators A100 Null Modem Adapter and A105 Additional 12 V Terminals Adapter Revision 4 09 C o p y r i g h t 2 0 0 0 2 0 0 9 C a m p b e l l S c i e n t i f i c I...

Page 2: ...US and International customers residing in countries served by Campbell Scientific Inc directly Affiliate companies handle repairs for customers within their territories Please visit www campbellsci...

Page 3: ...Use the Adobe Acrobat bookmarks tab for links to specific sections 1 General Description 1 2 Specifications 1 3 Wiring 2 4 A100 Null Modem Adapter 4 5 A105 12V Terminal Expansion Adapter 5 Figures 1 W...

Page 4: ......

Page 5: ...tific peripherals that would normally be connected to a datalogger These peripherals are typically modems linking different communications technologies e g telephone to radio The A105 Additional 12 V...

Page 6: ...RMS Protection automatic reset 85 C thermal reset breaker UL Approval UL 1950 AC Transformer CSI Model No 14014 Input Voltage 90 264 VAC 47 63 Hz Output Voltage 18 VDC Output Current max 1 3 Amps UL A...

Page 7: ...harged A battery must be attached for the charger to function correctly as a power supply CAUTION The leads from the transformer or solar panel are connected to the CHG terminals Polarity does not mat...

Page 8: ...tic 4 A100 Null Modem Adapter The A100 has two 9 pin CS I O ports with a null modem between them The ports are used to connect two 9 pin devices that would normally be connected to the CS I O port on...

Page 9: ...12 V 5 V 1 85 A Thermal Fuse FIGURE 3 Null Modem Connections 5 A105 12V Terminal Expansion Adapter The A105 adapter adds four 12 V terminals and four ground terminals to a CH100 or PS100 see Figure 4...

Page 10: ...PS100 and CH100 Power Supply and Charging Regulators 6...

Page 11: ......

Page 12: ...a Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Centro Caribe S A CSCC 300 N Cementerio Edificio Breller Santo Doming...

Reviews: