5.1.2 Step 2: ComPort Configuration
With the setup tree entered, you will now need to complete the configuration of
each element. Start with selecting the
ComPort
element at the root of the tree
(FIGURE
5-2
). Be sure that the
ComPort Connection
is correct for the
computer used as part of your base station, and make sure that the
Communications Enabled
box is checked.
Set the
Extra Response Time
and
ComPort Communication Delay
to
3
seconds
. Set the
Delay Hangup
to
200 ms
. This will prevent
LoggerNet
from
hanging up whenever there is a slight lag in transmission time, which is
common in satellite applications.