R.M. Young Wind Sentry
7.4.4.1 CR1000 Program
'CR1000
'Declare Variables and Units
Public Batt_Volt
Public WS_ms
Public WindDir
Units Batt_Volt=Volts
Units WS_ms=meters/second
Units WindDir=Degrees
'Define Data Tables
DataTable(Table1,True,-1)
DataInterval(0,60,Min,10)
WindVector (1,WS_ms,WindDir,FP2,False,0,0,0)
FieldNames("WS_ms_S_WVT,WindDir_D1_WVT,WindDir_SD1_WVT")
EndTable
'Main Program
BeginProg
Scan(5,Sec,1,0)
'Default Datalogger Battery Voltage measurement Batt_Volt:
Battery(Batt_Volt)
'03002 or 03101 RM Young Wind Sentry Wind Speed Sensor measurement - WS_ms:
PulseCount(WS_ms,1,1,1,1,0.75,0.2)
If WS_ms<0.21 Then WS_ms=0
'03002 or 03301 RM Young Wind Sentry Wind Direction Sensor measurement -
WindDir:
BrHalf(WindDir,1,mV2500,1,1,1,2500,True,0,_60Hz,352,0)
'Use mV5000 range and 5000 mV excitation for CR3000 and CR5000 dataloggers.
If WindDir>=360 OR WindDir<0 Then WindDir=0
'Call Data Tables and Store Data
CallTable(Table1)
NextScan
EndProg
7.4.4.2 CR10X Program
;{CR10X}
*Table 1 Program
01: 5.0000 Execution
Interval
(seconds)
1: Batt Voltage (P10)
1: 1
Loc
[
Batt_Volt
]
;03002 or 03101 RM Young Wind Sentry Wind Speed Sensor measurement - WS_ms:
2: Pulse (P3)
1: 1
Reps
2: 1
Pulse
Channel
1
3: 21
Low Level AC, Output Hz
4: 2
Loc [ WS_ms ]
5: 0.75
Multiplier
6: 0.2
Offset
15
Summary of Contents for 03002 R.M
Page 2: ......
Page 26: ...R M Young Wind Sentry 20 ...
Page 30: ...Appendix A Wind Direction Sensor Orientation A 4 ...
Page 37: ...Page 4 03002 5 90 D CABLE WIRING DIAGRAM ...
Page 38: ...Page 5 03002 5 90 D GENERAL ASSEMBLY REPLACEMENT PARTS ...
Page 39: ......