SPECIAL OPERATING NOTES
1. Check the shipping list in the front of the
manual and make sure that all the parts
checked off the list are with the weather station.
If any parts are missing please contact
Campbell Scientific, Inc. 435-753-2342.
2. When connecting the battery avoid shorting
the battery to the weather station base (Section
2.5.1).
3. Damage to the electronics will occur if
moisture builds up inside the weather station. A
moisture detection sensor is used to detect
excessive humidity levels. This reading must
be monitored and corrective action taken if
moisture is detected (Section 4).
4. The hex bolts sealing the squeeze plates at
each end of the canister must be tightened
every spring and fall to maintain seal integrity
(Section 4).