background image

eLeCtrICAL SAFety

 

Risk of electrical shock. Always 

  disconnect from power source before 

servicing. Servicing should be performed by authorized 
service center.

uSe AnD CAre

 

Never use plastic (PVC) pipe for  

  compressed air. Serious injury or  

 

death could result.

a. 

Before each use, inspect compressed air 
system and electrical components for signs of damage, 
deterioration, weakness or leakage. 

Repair or replace 

defective items before using.

b. 

Check all fasteners at frequent intervals for proper 
tightness.

c.  

Check air hoses for weak or worn condition before each 
use.

 Make sure all connections are secure.

d.

  Do not stand on or use the pump or unit as a handhold.

e.  

If the equipment should start to abnormally vibrate, STOP 
the engine/motor and check immediately for the cause. 

Vibration is generally a warning of trouble.

 

Never remove or attempt to adjust safety valve. 

  Keep safety valve free from paint and other  

 

 

accumulations.

f. 

Do not alter or tamper with the safety relief valve.

 In the 

event that the safety relief valve is tampered with, existing 
warranties shall be voided and Campbell Hausfeld disclaims 
any liability whatsoever for any loss, personal injury or 
damage.

 

Never attempt to repair or modify 

  a tank! Welding, drilling or any 

other modification will weaken the tank resulting in 
damage from rupture or explosion. Always replace worn or 
damaged tanks.

  Drain liquid from tank daily.

g. 

Make sure to drain tank regularly and inspect periodically 
for unsafe conditions such as rust formation and 
corrosion.

 Tanks rust from moisture build-up, which 

weakens the tank. 

h. 

Release air slowly when draining moisture or 
depressurizing the compressor system. 

Fast moving air will 

stir up dust and debris which may be harmful.

i. 

Do not remove any warning labels from the unit.

j. 

Store inside. 

Do not store outside or in direct sunlight.

Work AreA

a.  

Keep the work area clean and well lighted. 

Cluttered 

benches and dark areas increase the risks of electric shock, 
fire, and injury to persons. 

b.  

Keep bystanders, children, and visitors away while 
operating. 

Distractions are able to result in the loss of 

control. NEVER allow children in the work area.

 

Motors, electrical equipment 

  and controls can cause electrical 

arcs that will ignite a flammable gas or vapor. Never 
operate or repair in or near a flammable gas or vapor. 
Never store or spray flammable liquids or gases in the 
vicinity of the compressor.

c.  

To reduce fire hazard, keep engine/motor exterior free of 
oil, solvent, or excessive grease.

PerSonAL SAFety

a.  

Stay alert. Watch what you are doing and use common 
sense when operating the tool. Do not use the tool 
while tired or under the influence of drugs, alcohol, or 
medication. 

A moment of inattention while operating the 

tool increases the risk of injury to persons. 

 

Ensuring that the tool is used  

  only when the operator and all 

other personnel in the work area are wearing ANSI Z87 
eye protection equipment, and when required, other 
appropriate protection equipment such as head, hearing 
and foot protection equipment. Serious eye or permanent hearing loss 
could result.

b.  

Always wear hearing protection when using the tool. 

Prolonged exposure to high intensity noise is able to cause 
hearing loss. 

c. 

Always work in a well-ventilated area. Wear OSHA-
approved dust mask.

d. 

Dress properly. Do not wear loose clothing or jewelry. 
Contain long hair. Keep hair, clothing, and gloves away 
from moving parts. 

Loose clothes, jewelry, or long hair 

increases the risk of injury to persons as a result of being 
caught in moving parts. 

 

Compressor parts may be hot even if 

  the unit is stopped.

e. 

Keep fingers away from a running compressor

fast moving and hot parts will cause injury and/or 
burns.

f. 

  Do not overreach. Keep proper footing and 

balance at all times. 

Proper footing and balance 

enables better control of the tool in unexpected 
situations. 

WL6700 Series

www.chpower.com

Important Safety Information (Continued)

5

Summary of Contents for IN629500AV

Page 1: ...IKE A PRO Visit us at chpower com The Ultimate Portable Garage Air Compressor Operating Instructions and Parts Manual WL6700 Series Fran aise Page Fr 1 Espa ol p gina Sp 1 2009 Campbell Hausfeld Scott...

Page 2: ...ressor 9 Tool Recommendation for this Compressor 9 Assembly 10 Tools Required for Assembly 10 Handle Assembly 10 Inflation Hose Assembly 10 Installation 11 Location 11 Wheel Lock Foot Brake 11 Electri...

Page 3: ...ions WL6700 Series Running HP 1 7 ISO 1217 Free Air CFM 3 8 90 psi ISO 1217 Free Air CFM 5 6 40 psi ISO 1217 Tank Capacity gallons 18 22 26 or 30 Volts Phase 120 V single Amp Draw 15 Max Duty Cycle 50...

Page 4: ...sed existing warranties shall be voided and Campbell Hausfeld disclaims any liability whatsoever for any loss personal injury or damage General a To reduce the risks of electric shock fire and injury...

Page 5: ...work area clean and well lighted Cluttered benches and dark areas increase the risks of electric shock fire and injury to persons b Keep bystanders children and visitors away while operating Distract...

Page 6: ...requirements established by the American National Standards Institute Standard B19 3 1991 Safety Standard for Compressors for Process Industries Contact your air compressor manufacturer for informatio...

Page 7: ...ps are complete and until you have read and understood the entire operator s manual u To reduce the risk of injury if any parts are missing do not attempt to assemble the air compressor until the miss...

Page 8: ...off Press firmly Motor Protection If the unit is over worked a thermal switch will shut unit off If this happens turn unit OFF the ON OFF Switch wait 30 minutes to cool turn ON the ON OFF Switch again...

Page 9: ...s Intermittent Use Short powerful bursts Air chisels Air drills Automotive spray guns Die grinders Tools Not Recommended Cut off tools Dual action sanders Highspeed sanders Jitterbug sanders Straight...

Page 10: ...ends of the recoil hose to prevent leaks 2 Thread the coil hose into the fitting on the shroud Use 2 adjustable wrenches to tighten the connection by holding the bottom wrench steady and tightening wi...

Page 11: ...that looks like the plug illustrated in Figure 12 Only connect the product to an outlet having the same configuration as the plug Do not use an adapter with this product In the event of an electrical...

Page 12: ...form into droplets as it comes from an air compressor pump When humidity is high or when a compressor is in continuous use for an extended period of time this moisture will collect in the tank When u...

Page 13: ...kwise If regulator knob is turned and a click is no longer heard DO NOT turn knob counter clockwise 13 WL6700 Series www chpower com Operation Continued Reassembly If you do turn the regulator knob to...

Page 14: ...flation 7 When inflation is complete blow gun can be attached to the clip that is molded on the side of the top shroud for convenient storage To Use Compressor For Air Tool Usage 1 Connect 1 4 inch in...

Page 15: ...40 50 psi If the safety valve does not allow air to be released when you pull on the ring or if it does not close automatically it MUST be replaced Drain Tank 1 Turn compressor off at foot pedal swit...

Page 16: ...ssor requiring no lubrication Thermal Overload Protector This compressor is equipped with an automatic reset thermal overload protector which will shut off motor if it becomes overheated If thermal ov...

Page 17: ...17 WL6700 Series www chpower com Service Record Date Maintenance Performed Replacement Components Required...

Page 18: ...connections fittings tubing etc 1 Check all connections with soap and water solution Tighten or remove and apply pipe dope or pipe tape to the threads then reassemble 2 Open tank drain 2 Close drain...

Page 19: ...Motor assembly kit Includes 2 3 6 7 10 12 14 WL019100SJ 1 2 Cylinder gasket 1 3 Intake valve 1 4 Valve plate 1 5 Exhaust valve 1 6 Head gasket 1 7 Exhaust valve gasket 1 8 Head WL010500AV 1 9 Piston...

Page 20: ...eld Serial number if any Attn Customer Service Part description and number as shown in parts list 100 Production Drive Harrison OH 45030 U S A Figure 22 Repair Parts Illustration for The Ultimate Port...

Page 21: ...ff Switch ST196400AV 1 33 On Off Pedal WL044500AV 1 34 Eccentric Cover WL044400AV 1 35 Motor Bracket BA018300AV 1 Ref Part No Description No Qty Ref Part No Description No Qty 36 Wheel 10 OD Black Hub...

Page 22: ...Accident purchaser s abuse neglect or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety devices If such safety devices are removed...

Page 23: ...KE A PRO Visit us at chpower com L ultime compresseur d air de garage portable Instructions d Utilisation et Manual de Pi ces S rie WL6700 ENGLISH Page 1 Espa ol p gina sp 1 2009 Campbell Hausfeld Sco...

Page 24: ...10 Outils requis pour l assemblage Fr 10 Assemblage de poign e Fr 10 Assemblage du tuyau de gonflement Fr 10 Installation Fr 11 Endroit Fr 11 Verrou de roue frein pied Fr 11 Installation lectrique Fr...

Page 25: ...1217 m min pi min d air libre 0 107 m min 621 kPa 3 8 90 lb po ISO 1217 m min pi min d air libre 158 m min 276 kPa 5 6 40 lb po ISO 1217 Capacit de r servoir 68 13 L 83 27 L 98 41 L 113 55 L 18 22 26...

Page 26: ...as utilis simultan ment les garanties en existance seront annul es et Campbell Hausfeld d nie toute responsabilit pour n importe quelle perte blessure ou dommage G n ralit a Pour r duire les risques d...

Page 27: ...blessures et ou des br lures f Ne pas trop se pencher Garder bon pied et bon quilibre en tout temps Ceci permet d avoir un meilleur contr le de l outil dans les situations impr vues S curit lectrique...

Page 28: ...an National Standards Institute Standard B19 3 1991 Safety Standard for Compressors for Process Industries Contacter le fabricant du compresseur pour plus d informations Service a Dissiper la pression...

Page 29: ...de terminer toutes les tapes d assemblage et d avoir lu et compris tout le manuel de l op rateur u Pour r duire les risques de blessure s ils manquent des pi ces ne pas essayer d assembler le compress...

Page 30: ...r en marche et l arr ter Pressez fermement PROTECTION DU MOTEUR Si l appareil fonctionne trop un interrupteur thermique l arr tera Si ceci se produit mettre l interrupteur MARCHE ARR T la position OFF...

Page 31: ...sage intermittent Courtes salves puissantes Burins pneumatiques Perceuses pneumatiques Pistolets de pulv risation automobiles Meules rectifier Outils non recommand s Machines tron onner Ponceuses doub...

Page 32: ...ans le raccord sur l paulement Utiliser 2 cl s ajustables pour resserrer la connexion en tenant la cl inf rieure sans bouger et en resserrant avec la cl sup rieure voir la figure 10 3 Visser la souffl...

Page 33: ...iche de mise la terre comme celle indiqu e sur la Fig 12 Brancher ce produit seulement une prise avec la m me configuration de la fiche Ne pas utiliser un adaptateur avec ce produit Dans l venement d...

Page 34: ...idit dans l air comprim L humidit dans l air comprim forme des goutelettes en arrivant de la pompe du compresseur Si l humidit est lev e ou si le compresseur est utilis continuellement cette humidit s...

Page 35: ...rner le bouton dans le sens antihoraire Si le bouton de r gulateur est tourn et si l on n entend plus de clic il ne faut PAS tourner le bouton dans le sens antihoraire Fonctionnement Suite Remontage S...

Page 36: ...tique 1 Connecter le bouchon industriel de 6 3 mm 1 4 po pour s parer le tuyau bouchon et tuyau non inclus 2 Connecter le tuyau s par au coupleur sous le r gulateur de pression en tirant sur le mancho...

Page 37: ...pied 2 V rifier la pression d air dans le r servoir Pour vidanger correctement le r servoir de toute condensation la pression du r servoir doit tre entre 138 et 414 kPa 20 60 lb po Le syst me de vidan...

Page 38: ...otecteur de surcharge thermique Si le protecteur de surcharge thermique coupe le moteur OFF maintes reprises rechercher les causes suivantes Si le protecteur de surcharge thermique coupe le moteur OFF...

Page 39: ...Fr 17 Mod le WL6701 tat de service Date Entretien ex cut l ments de remplacement requis...

Page 40: ...s raccords tuyaux etc 1 V rifier tous les raccordements avec de l eau savonneuse Resserrer ou retirer et appliquer aux filets un produit scellant ou de ruban pour filets puis remonter 2 Ouvrir le robi...

Page 41: ...Joint d tanch it de cylindre 1 3 Soupape d admission 1 4 Plaque de soupape 1 5 Soupape d chappement 1 6 Joint d tanch it de culasse 1 7 Joint de soupape d chappement 1 8 Culasse WL010500AV 1 9 Montage...

Page 42: ...usfeld Code imprim sur l outil Attn Customer Service Description de la pi ce et son num ro 100 Production Drive Harrison OH 45030 U S A Figure 22 Illustration des pi ces de r paration pour l ultime co...

Page 43: ...0AV 1 35 Support de moteur BA018300AV 1 36 Roue moyeu noir de 25 4 cm 10 po de DE WA004000AV 2 No de Num ro Ref Description de Pi ce Qt No de Num ro Ref Description de Pi ce Qt 37 Boulon d arbre de ro...

Page 44: ...r l acheteur la n gligence ou le manque de faire fonctionner les produits selon les instructions comprend aussi l enlevage ou la modification de n importe quel appareil de s ret Si ces appareils de s...

Page 45: ...E A PRO Visit us at chpower com El m ximo compresor de aire port til para el garaje Manual de Instrucciones y Lista de Piezas serie WL6700 ENGLISH Page 1 Fran aise Page fr 1 2009 Campbell Hausfeld Sco...

Page 46: ...ra el Ensamblaje Sp 10 Ensamblaja del Mango Sp 10 Ensamblaja de la Manguera Sp 10 Instalaci n Sp 11 Ubicaci n Sp 11 Bloqueo de Rueda Freno de Pie Sp 11 Instalacion Electrica Sp 11 Conexion a Tierra Sp...

Page 47: ...rvicio 1 7 HP ISO 1217 Aire libre CFM m3 min 3 8 90 psi ISO 1217 0 108 6 2 bar Aire libre CFM m3 min 5 6 40 psi ISO 1217 0 158 2 8 bar Capacidad del tanque 68 13 L 83 27 L 98 41 L 113 55 L 18 22 26 o...

Page 48: ...el sistema de seguridad y alarma todas la garant as se anular n y la compa ia Campbell Hausfeld no asumir NINGUNA responsabilidad por p rdidas heridas personales o da os General a Para reducir el ries...

Page 49: ...zar lugares alejados Mantenga un buen soporte y equilibrio en todo momento Un soporte y equilibrio adecuados permiten un mejor control de la herramienta en situaciones inesperadas Seguridad El ctrica...

Page 50: ...eamericanaANSI en el c digo B19 3 1991 sobre seguridad y est ndares para compresores de aire industriales Contacte al fabricante de su compresor de aire para mayor informaci n Servicio a Para liberar...

Page 51: ...t n completos y hasta que haya le do y entendido todo el manual del operador u Para reducir el riesgo de lesiones si falta alguna pieza no intente ensamblar el compresor de aire hasta obtener e instal...

Page 52: ...compresor Presione con firmeza PROTECCI N DEL MOTOR Si la unidad sufre una sobrecarga un interruptor t rmico la apaga Si esto pasa apague la unidad con el interruptor ON OFF espere 30 minutos para qu...

Page 53: ...corta duraci n Formones neum ticos Taladros neum ticos Pistolas pulverizadoras para veh culos Amoladoras de troqueles Herramientas no recomendadas Herramientas de corte Lijadoras de doble acci n Lija...

Page 54: ...spiral en la conexi n en la cubierta Use 2 llaves ajustables para apretar la conexi n sosteniendo firme la llave inferior y apretando con la llave superior vea la Figura 10 3 Atornille la pistola neum...

Page 55: ...nales de 120 voltios y tiene un enchufe para conexi n a tierra similar al de la Figura 12 Conecte el producto nicamente a un tomacorriente que tenga la misma configuraci n que el enchufe No utilice un...

Page 56: ...convierte en gotas a medida que sale del cabezal del compresor de aire Cuando el nivel de humnedad es muy alto o cuando el compresor ha estado en uso continuo por mucho tiempo sta se acumular en el ta...

Page 57: ...de seguridad ASME De vez en cuando debe halar el anillo con la mano para chequear esta v lvula Vea la Figura 13 Si hay una fuga de aire despu s de haber soltado el anillo o si la v lvula est atascada...

Page 58: ...inflado el pistola neum tica puede ser atada al sujetador que est moldeado en el lado de la cubierta superior para el almacenamiento conveniente Uso del Compresor para Herramientas Neum tica 1 Conecte...

Page 59: ...2 Verifique la presi n de aire en el tanque Para drenar correctamente el tanque de la condensaci n la presi n de tanque deber a estar entre 20 60 psi 1 38 4 14 bar El sistema de drenaje no trabaja si...

Page 60: ...est equipado con un protector autom tico contra sobrecarga t rmica que apagar el motor cuando ste se sobrecaliente Si el protector t rmico apaga el motor con mucha frecuencia puede ser por lo siguient...

Page 61: ...Sp 17 Modelo WL6701 Registro de Servicio Fecha Maintenimiento efectuado Repuestos requeridos...

Page 62: ...1 Conexiones flojas conexiones tuber as etc 1 Revise todas las conexiones con una soluci n de agua y jab n Apriete o retire y aplique sellador o cintas para roscas luego vuelva a ensamblar 2 Drenaje...

Page 63: ...3 6 7 10 12 14 WL019100SJ 1 2 Empaque del cilindro 1 3 V lvula de entrada 1 4 Placa de la v lvula 1 5 V lvula de salida 1 6 Empaque de la culata 1 7 Empaque de la v lvula de salida 1 8 Culata WL010500...

Page 64: ...N mero de serie si tiene Attn Customer Service Descripci n y n mero de la pieza como se muestra 100 Production Drive en la lista de repuestos Harrison OH 45030 U S A Figura 22 Ilustraci n de las pieza...

Page 65: ...34 Tapa de la exc ntrica WL044400AV 1 35 Soporte del motor BA018300AV 1 36 Rueda di m int 25 4 cm 10 pulg cubo negro WA004000AV 2 No de N mero de Ref Descripci n Repuesto Ctd No de N mero de Ref Descr...

Page 66: ...ones suministrado tambi n debe incluir la desconexi n o modificaci n de los instrumentos de seguridad Si dichos instrumentos de seguridad son desconectados la garant a quedar a cancelada D Los ajustes...

Page 67: ...23 www chpower com Notes Notas...

Page 68: ...24 Notes Notas Operating Instructions and Parts Manual u Instructions d Utilisation et Manual de Pi ces u Manual de Instrucciones y Lista de Piezas www chpower com...

Reviews: