4
Operating Instructions and Assembly Instructions
Airless Paint Sprayers
SkIN INjECTION HAzARD:
●
High pressure spray can inject toxins
into blood stream. If injection
occurs, seek emergency medical
treatment.
use a face mask/respirator
and protective clothing
when spraying. Always
spray in a well ventilated area to
prevent health and fire hazards. Refer
to Material Safety Data Sheets (MSDS)
of spray material for details.
●
Never try to stop leaks with any
part of your body.
●
This system is capable of producing
3000 psi (20 500 kPa). Use only
Campbell Hausfeld replacement
parts rated at 3000 psi (20 500 kPa)
or higher.
To reduce the risk of
skin injection:
●
Do not aim the
gun at, or spray,
any person or
animal.
●
Keep hands and other body parts
away from the discharge. For
example, do not try to stop leaks
with any part of the body.
●
Do not clean spray tip while it is
attached to the spray gun. Remove
spray tip from gun to clean tip
guard.
●
Always use the nozzle tip guard. Do
not spray without nozzle tip guard
in place.
●
Do not remove tip while cleaning
the pump.
●
Only use a nozzle tip specified by
the manufacturer.
●
Use caution when cleaning and
changing nozzle tips. Before
www.chpower.com
removing the nozzle tip, follow
the manufacturer’s instructions for
turning off the unit and relieving
the pressure.
●
Do not leave the unit energized or
under pressure while unattended.
When not in use turn off the
unit and relieve the pressure in
accordance with the manufacturer’s
instructions.
●
High pressure spray is able to inject
toxins into the body and cause
serious bodily injury. In the event
that injection occurs, seek medical
attention immediately.
●
Check parts for signs of damage.
Replace any damaged parts.
●
This spray gun is rated for 3000 psi
(20 500 kPa). Do not use on systems
designed to produce more than
3000 psi (20 500 kPa).
●
Always engage the trigger lock
when not spraying. Verify the
trigger lock is functioning properly.
• To lock (engage): rotate tabs on
lock to horizontal position.
• To unlock (disengage) to spray:
rotate tabs on lock to vertical
position.
NOTE:
If gun sprays while in the locked
position follow instructions in Spray
Gun Maintenance section for trigger
lock.
●
Verify that all connections are
secure before operating. Do not
use pliers to tighten or loosen high
pressure connections.
●
Know how to stop your unit
and bleed pressure quickly. Be
thoroughly familiar with the
controls.
●
Motor is equipped with an
automatic thermal overload. Motor
will restart without warning, after
cooling.
Never aim or
spray at yourself
or anyone else or serious injury could
occur.
LOCKED
TO UNLOCK
UNLOCKED
TO LOCK