background image

Troubleshooting Chart

Symptom

Possible Cause(s)

Corrective Action

1. Switch in OFF position

2. No electrical power at wall outlet

3. Compressor has reached automatic

shut-off pressure

4. Motor overheated

5. Loose electrical connection

6. ON / OFF switch bad

7. Pressure switch bad

8. Defective motor

1. Lack of proper ventilation/room

temperature too high

2. Excessive air usage, compressor too

small

1. Open tank drain valve

2. Loose connections (fittings, tubing,

air hose, any connections, etc.)

3. Tank leaks

1. Excessive air usage, compressor too

small

2. Open tank drain valve

3. Loose connections (fittings, tubing,

air hose, any connections, etc.)

4. Pump wore out

1. Excessive water in tank

2. High humidity

1. Defective pressure switch

2. Defective safety valve

1. Make sure compressor is plugged in and switch is ON

2. Check circuit breaker or fuse at electrical panel.

3. Release air from tank until compressor restarts

automatically

4. Allow compressor to cool for approximately 30

minutes so thermal overload switch will reset. Make

sure compressor is run in a clean, well-ventilated area

where temperature will not exceed 100°F.

5. Check all electrical connections

6. Replace ON / OFF switch

7. Replace pressure switch

8. Replace pump / motor assembly

1. Move compressor to a clean,well ventilated area

where temperature will not exceed 100°F.

2. Decrease usage or purchase unit with higher air

delivery (SCFM)

1. Close tank drain valve

2. Check all connections with soap and water solution.

If a leak is detected, tighten. Or remove fitting and

apply pipe tape to threads and reassemble.

Do not disassemble check

valve. With air in tank, bleed tank first.

3. Check entire tank for leaks with soap and water

solution.

1. Decrease usage or purchase unit with higher air

delivery (SCFM)

2. Close tank drain valve

3. Check all connections with soap and water solution.

If a leak is detected, tighten. Or remove fitting and

apply pipe tape to threads and reassemble.

4. Replace pump / motor assembly

1. Drain tank, tilt tank to remove moisture

2. Move to area of less humidity; use air line filter

1. Replace pressure switch

2. Replace safety valve with genuine replacement part

Compressor will not run

Thermal overload

protector cuts out

repeatedly

Tank pressure drops

when compressor shuts

off

Compressor runs

continuously / air

output lower than

normal

Excessive moisture in

discharge air

Safety valve pops open

FP2090, FP2091, FP2094 Series

5

Summary of Contents for FP2090 Series

Page 1: ...MAY cause damage to equipment CALIFORNIA PROPOSITION 65 This product or its power cord contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm...

Page 2: ...iodically for unsafe conditions such as rust formation and corrosion 14 Fast moving air will stir up dust and debris which may be harmful Release air slowly when draining moisture or depressurizing th...

Page 3: ...Pressure Gauges There are two gauges located next to the regulator These gauges read air pressure in pounds per square inch psi The larger gauge shows pressure at the outlet Make sure this gauge read...

Page 4: ...underneath tank CLEANING Turn power OFF and clean dust and dirt from pump cover tank and air lines IMPORTANT Unit should be located as far from spraying area as hose will allow to prevent over spray...

Page 5: ...exceed 100 F 5 Check all electrical connections 6 Replace ON OFF switch 7 Replace pressure switch 8 Replace pump motor assembly 1 Move compressor to a clean well ventilated area where temperature wil...

Page 6: ...E Items or service that are normally required to maintain the product e g lubricants filters and gaskets etc F Additional items not covered under this warranty 1 Any component damaged in shipment or a...

Page 7: ...OSITION 65 DE CALIFORNIE Ce produit ou son cordon contient des produits chimiques qui de l avis de l tat de Californie peut causer le cancer et des anomalies cong nitales ou autres probl mes de reprod...

Page 8: ...ifier un r servoir Le soudage per age ou autre modifications peuvent affaiblir le r servoir et peuvent r sulter en dommage de rupture ou d explosion Toujours remplacer un r servoir us fendu ou endomma...

Page 9: ...ettre en marche le compresseur Mettre l interrupteur la position OFF O pour teindre le compresseur Cet interrupteur devrait tre dans la position OFF O pendant le branchement ou le d branchement du cor...

Page 10: ...et ensuite dissiper toute la pression du syst me avant d essayer d installer de r parer de d placer ou de proc der l entretien L entretien doit tre r alis seulement par un repr sentant de service aut...

Page 11: ...Ou retirer le raccord et appliquer un ruban tuyau sur les filets puis remonter Ne pas d monter le clapet Avec de l air dans le r servoir purger le r servoir d abord 3 V rifier tout le r servoir avec d...

Page 12: ...ints d tanch it s par exemples F Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Toutes pi ces d tach es endommag es pendant l exp dition n importe quelle panne caus e par un m...

Page 13: ...f brica para suministrarle aire respirable Antes de utilizarlos con este fin deber instalarle un sistema de seguridad y alarma incorporado a la l nea Este sistema adicional es necesario para filtrar...

Page 14: ...ar las v lvulas de seguridad Igualmente debe evitar que se le acumule pintura u otros materiales Nunca trate de reparar o modificar el tanque Si lo suelda taladra o modifica de cualquier otra manera e...

Page 15: ...ctar o desconectar el cord n el ctrico del tomacorrientes o para cambiar herramientas Interruptor de presi n ubicado internamente Al encender el compresor ON este interruptor lo apaga autom ticamente...

Page 16: ...interruptor en OFF O desenchufe el cable el ctrico y drene el aire del tanque Mantenimiento Desconecte el cord n el ctrico del tomacorrientes y libere toda la presi n del sistema antes de tratar de i...

Page 17: ...osici n OFF O apagado 2 Desenchufe el cord n del tomacorrientes de pared y envu lvalo alrededor del mango para prevenir da os cuando no se use 3 Con las gafas de seguridad puestas descargue el aire de...

Page 18: ...Verifique todas las conexiones el ctricas 6 Reemplace el interruptor ON OFF 7 Cambie el interruptor de presi n 8 Reemplace el ensamble de la bomba motor 1 Mueva el compresor a un rea limpia y bien ve...

Page 19: ...onales no cubiertos bajo esta garant a 1 Cualquier componente da ado durante el env o o cualquier da o ocasionado por haber instalado u operado la unidad bajo condiciones contrarias a lo indicado en l...

Page 20: ...Notes Notes Notas FP2090 FP2091 FP2094 20 Oilless Compressors Compresseur Sans Huile Compresores Sin Aceite...

Reviews: