Air Compressors
Maintenance
Release all
pressure and
disconnect power before making any
repair.
1. Check compressor for any visible
problems.
2. Pull ring on safety valve and allow it to
snap back to normal position.
Safety valve must
be replaced if it
cannot be actuated or it leaks air after ring
is released.
3. With compressor shut off reduce tank
pressure below 10 psi, then drain
moisture from tank daily to avoid tank
corrosion. The procedure to drain tank
depends on the compressor type:
For pancake units:
Drain by tilting
tank.
For horizontal units:
No tilting is
necessary to drain.
!
WARNING
!
WARNING
4. Turn power OFF and clean dust and dirt
from motor, tank, air lines and pump
cooling fins.
NOTE:
This unit has no air filter to
maintain.
IMPORTANT:
Unit should be located as
far from spraying area as hose will allow.
LUBRICATION
This is a compressor that requires no
additional lubrication.
THERMAL OVERLOAD PROTECTOR
This compressor is
equipped with an
automatic reset thermal overload
protector which will shut off motor if it
becomes overheated.
!
CAUTION
If thermal overload protector shuts motor
OFF frequently look for the following
causes.
1. Low voltage.
2. Wrong gauge wire or length of
extension cord.
3. Lack of proper ventilation.
The motor must be
allowed to cool
down before start-up is possible. The
motor will automatically restart without
warning if left plugged into electrical
outlet, if the motor is turned on.
STORAGE
1. When not in use, hose and compressor
should be stored in a cool dry place.
2. Tank should be drained of moisture.
3. Hose should be disconnected and hung
open ends down to allow any moisture
to drain.
!
CAUTION
Drain
Cock
Figure 8
Figure 7
www.chpower.com
Troubleshooting Chart
Symptom
Possible Cause(s)
Corrective Action
1. Loss of power or overheating
2. No electrical power
3. Breaker open/blown fuse
4. Thermal overload open
5. Pressure switch bad
6. Tank is full of air
1. Low voltage
2. Wrong gauge wire or length of
extension cord
3. Shorted or open motor winding
4. Defective check valve or unloader
1. Check for proper use of extension cord (see
EXTENSION CORDS, page 3)
2. Plugged in? Check fuse/breaker or motor overload
3. Reset breaker or replace blown fuse.
4. Motor will restart when cool
5. Replace
6. Compressor will turn on when tank pressure drops to
cut in pressure
1. Check with voltmeter
2. Check gauge chart, under Operation for proper
gauge wire and cord length
3. Take compressor to authorized Campbell Hausfeld
service center
4. Take compressor to authorized Campbell Hausfeld
service center
Compressor will not run
Motor hums but cannot
run or runs slowly
Problema
Posible(s) Causa(s)
Acción a Tomar
1. Pérdida de potencia o se
sobrecalienta
2. No hay energía eléctrica
3. Disyuntor abierto/fusible quemado
4. Protector térmico desconectado
5. Presostato dañado
6. El tanque está lleno de aire
1. Voltaje bajo
2. Cordón de extensión inadecuado
3. Defecto de la bobina del motor
4. Válvula de chequeo o desfogue
defectuosa
1. Fusible inadecuado, circuito
sobreacrgado
2. Cordón de extensión inadecuado
3. Válvula de chequeo o desfogue
defectuosa
1. Voltaje bajo
2. Poca ventilación/temperatura
ambiental muy alta
3. Cordón de extensión inadecuado
1. Chequee el cordón de extensión adecuado (vea la
sección CORDONES DE EXTENSION, página 3)
2. ¿Está conectado? Chequee el fusible/cortacircuito o
protector de sobrecarga del motorfuse/breaker or
motor overload
3. Reposicione el disyuntor o reemplace el fusible
quemado
4. Espere a que el motor se enfrie
5. Reemplácelo
6. El compresor se encenderá cuando la presión del
tanque disminuya a la presión de arranque
1. Chequee con un voltimetro
2. Chequee la tabla sobre los calibres y longitudes
adecuadas del cordón
3. Lleve el compresor a un centro de servicio Campbell
Hausfeld autorizado
4. Lleve el compresor a un centro de servicio Campbell
Hausfeld autorizado
1. Cerciórese de que está usando el fusible adecuado.
Desconecte los otros artefactos del circuito o conecte
el compresor a otro circuito
2. Chequee la tabla en la sección de funcionamiento
3. Lleve el compresor a un centro de servicio Campbell
Hausfeld autorizado
1. Chequée con un voltimetro
2. Mueva el compresor a un área bien ventilada
3. Chequée la tabla en la sección de funcionamiento
Compresor no funciona
Motor hace ruido pero
no funciona o funciona
lentamente
Fusibles/cortacircuito se
activa con frecuencia
El protector de
sobrecarga térmica se
activa constantemente
Guía de Diagnóstico de Averías