background image

CL154000AV

 

www.campbellhausfeld.com

 

3

All hoses and fittings must be the correct 
size and tightly fastened. Refer to Chart 1 
for minimum sizes. 

Tool Air Consumption

Hose ID

Less than 9 SCFM @ 100% usage

1/4 inch

9 to 34 SCFM @ 100% usage

3/8 inch

Greater than 34 SCFM @ 100% usage

1/2 inch

Chart 1 

- Suggested minimum hose diameter to 

use based on 50 ft length hose and continuous 
SCFM rating of tool. The use of fittings and longer 
hose may require a larger diameter hose to be 
used.

 

Do not use  

  hoses or fittings 

that are damaged or deteriorated.
 

Never carry a tool  

  by the hose or 

pull the hose to move the tool or a 
compressor. Keep hoses away from 
heat, oil and sharp edges. Replace any 
hose that is damaged, weak or worn. 

luBRIcatIon

Air tools require lubrication throughout 
the life of the tool and is the owner’s 
responsibility. Failure to lubricate the air 

12. Keep ALL nuts, bolts and screws 

tight and ensure equipment is in safe 
working condition.

13. ALwAYS secure workpiece in a vise 

or clamp.

14. NEVER point an air tool at oneself 

or any other person. Serious injury 
COULD occur.

15. Use steady, even pressure when 

using tool. Do not force. Too much 
pressure can cause blade to break or 
overheat.

Operation

set-up InstRuctIons

Air tools require a supply of clean, dry air 
at 90 PSI (6.2 bar). An air supply system 
with filter, regulator, and lubricator (FRL) 
as shown in Figure 1 should be used.
Campbell Hausfeld FRL model PA2104 
(3/8 inch) or PA2114 (1/2 inch) is 
recommended.
water in the air supply can damage the 
tool. Drain condensate from compressor 
tank and filter daily.

Option 2: 3 piece combo  

Filter, Regulator, and Lubricator

Filter

Lubricator

Regulator

Option 1: Individual components

Figure 1

Summary of Contents for CL154000AV

Page 1: ...imminently hazardous situation which if not avoided WILL result in death or serious injury Warning indicates a potentially hazardous situation which if not avoided COULD result in death or serious in...

Page 2: ...Protect yourself and others by observing all safety information Failure to comply with instructions could result in personal injury and or property damage Retain instructions for future reference 4 D...

Page 3: ...re lubrication throughout the life of the tool and is the owner s responsibility Failure to lubricate the air 12 Keep all nuts bolts and screws tight and ensure equipment is in safe working condition...

Page 4: ...ith an air line lubricator installed as part of the air piping system See Figure 1 Use Campbell Hausfeld air tool oil ST127000AV or equivalent ISO grade 32 oil Manual lubrication If an air line lubric...

Page 5: ...he tool or a compressor Keep hoses away from heat oil and sharp edges Replace any hose that is damaged weak or worn Blade Type Material Being Cut Blade Type Metal Fine Tooth Wood Coarse Tooth Chart 2...

Page 6: ...safety guidelines in that section Trigger the saw only once or twice because more oil needs to remain in it for storage Technical Service For information regarding the operation or repair of this prod...

Page 7: ...equire a hose with an I D of 1 2 or larger depending on the total length of the hose 5 b Do not use multiple number of hoses connected together with quick connect fittings This causes additional press...

Page 8: ...h instructions shall also include the removal or alteration of any safety devices If such safety devices are removed or altered this warranty is void D Normal adjustments which are explained in the ow...

Page 9: ...es graves Avertissement indique une situation hasardeuse potentielle qui PEUT r sulter en perte de vie ou blessures graves Attention indique une situation hasardeuse potentielle qui PEUT r sulter en b...

Page 10: ...de changer des outils et accessoires ou de proc der une op ration d entretien Il est N CESSAIRE de porter des lunettes de s curit et une protection auditive durant l utilisation 5 NE PAS porter de v...

Page 11: ...dommages et perforations NE PAS transporter l outil par le tuyau d air 10 NE JAMAIS appuyer sur la g chette de l outil tant que celui ci n est pas en contact avec l objet de travail Les accessoires D...

Page 12: ...254 L min pour une utilisation 100 1 4 po 254 963 L min pour une utilisation 100 3 8 po Sup rieure 963 L min pour une utilisation 100 1 2 po Tableau 1 Diam tre minimum sugg r du tuyau utiliser pour un...

Page 13: ...e se met sortir de l orifice d chappement d air une fois que l air est sous pression 5 Utiliser la pression r guli re et gale pendant l op ration de l outil Ne pas forcer La pression excessive peut ca...

Page 14: ...Pi ces De Rechange Pour des renseignements sur la commande de pi ces de rechange appeler sans co t le num ro 1 855 504 5678 S il vous pla t fournir l information suivante Num ro de Mod le Code estamp...

Page 15: ...ands volumes d air peuvent n cessiter un tuyau de diam tre int rieur d au moins 12 7 mm 1 2 po suivant la longueur totale du tuyau 5 b Ne pas utiliser plusieurs tuyaux branch s ensemble avec des racco...

Page 16: ...t Si ces appareils de s ret sont enlev s ou modifi s la garantie sera annul e D R glages normaux qui sont expliqu s dans le s manuel s d utilisation accompagnant le produit E Articles ou services qui...

Page 17: ...onhecer essas informa es observe os seguintes s mbolos Perigo indica uma situa o eminentemente perigosa que se n o for evitada causar a morte ou infort nios gravosos Aviso indica uma situa o potencial...

Page 18: ...nto A queda de press o entre o compressor e a ferramenta precisa ser compensada no compressor Libere TODA a press o do sistema antes de tentar instalar utilizar reposicionar ou realizar qualquer manut...

Page 19: ...e estar firmemente presas Consulte a Tabela 1 para tamanhos m nimos usar qualquer ferramenta se ocorrer desconforto dorm ncia formigamento ou dor e consulte um m dico 8 Verifique se as mangueiras de...

Page 20: ...i metro m nimo da mangueira sugerido para usar com base em mangueira de comprimento de 15 25 metros e classifica o L min cont nua da ferramenta A utiliza o de conex es e mangueira mais longa pode exig...

Page 21: ...se aplica a press o pneum tica 5 Aplique press o constante e uniforme ao usar a ferramenta N o aplique for a Press o em excesso pode fazer com que a l mina quebre ou superaque a 6 Escolha a l mina co...

Page 22: ...or favor entre em contato com o centro de assist ncia t cnica Campbell Hausfeld mais pr ximo INFORMA ES SOBRE AS PE AS DE REPOSI O Para obter informa es sobre onde pedir pe as de reposi o ligue gr tis...

Page 23: ...a mangueira de 1 2 pol de di metro interno ou maior dependendo da extens o total da mangueira 5 b N o use v rias mangueiras ligadas por conex es r pidas Isso causa mais quedas de press o e reduz a cap...

Page 24: ...m a retirada ou altera o de qualquer dispositivo de seguran a Se tais dispositivos de seguran a forem retirados ou alterados esta garantia ser anulada D Ajustes normais que s o explicados no manual d...

Page 25: ...e o heridas de gravedad sto le indica que hay una situaci n que PODRIA ocasionarle la muerte o heridas de gravedad sto le indica que hay una situaci n que PODRIA ocasionarle heridas no muy graves sto...

Page 26: ...uando no est en uso y antes de cambiar herramientas accesorios o efectuar mantenimiento Use SIEMPRE protecci n para los o dos y gafas de seguridad durante el funcionamiento 5 NO use ropa suelta bufand...

Page 27: ...Tabla 1 para conocer los tama os m nimos 9 Proteja las l neas de aire de da os o perforaciones NO lleve la herramienta por la manguera de aire 10 NUNCA oprima el gatillo a menos que la herramienta es...

Page 28: ...7 mm Tabla 1 El di metro m nimo sugerido de la manguera para usar basado en una manguera de 15 25 m de largo y calificaci n continua L min de la herramienta El uso de conexiones y una manguera m s la...

Page 29: ...apl quele una presi n constante para operar la herramienta No force la herramienta La presi n excesiva podr a ocasionar que la cuchilla se quiebre o se sobrecaliente 6 Seleccione la cuchilla adecuada...

Page 30: ...feld m s cercano a su domicilio Informaci n sobre Repuestos Para obtener informaci n con respecto a piezas de repuesto pedidas llame sin costo al 1 855 504 5678 S rvase suministrarnos la siguiente inf...

Page 31: ...uerir una manguera con un D I de 12 7mm 1 2 o superior seg n la longitud total de la manguera 5 b No utilice una serie de mangueras conectadas con conectores r pidos sto ocasiona bajas de presi n adic...

Page 32: ...i n de los instrumentos de seguridad Si dichos instrumentos de seguridad son desconectados la garant a quedar a cancelada D Los ajustes normales explicados en el los manual es suministrado s con el pr...

Reviews: