FT-305 Wiltshire Fountain
Three people are recommended for the installation of this fountain!
Revised April 23, 2018
Assemble your fountain on a level surface capable of holding a minimum of 1001 pounds with an approximate
2.75 square foot footprint.
FT-114I (140 lbs)
20”L x 20”W x 6”H
FT-114H (150 lbs)
15.5”L x 15.5”W x 18”H
FT-114G (327 lbs)
47”W x 6.5”H
FT-305C (52 lbs)
13"W x 14.25"H
FT-305B (65 lbs)
25"W x 8.25"H
FT-305A (37 lbs)
7.75"W x 16.5"H
FT-114F (3 lbs)
5.25”L x 2”W x 4”H
1.
Place the base (FT-114I) into position where the fountain will be installed, ensuring that
it is level.
a.
Note: Check that all components are leveled as the fountain is assembled.
2.
Center the large pedestal (FT-114H) over the base.
3.
Assemble the fountain plumbing
a.
Attach the 3/4” clear tubing end of the tubing assembly to the pump outlet.
i.
Note: Do not use the adapter/flow adjuster the came with the pump.
b.
Place the stopper around the pump cord approximately 6” from the pump.
4.
Center the large bowl (FT-114G) over the large pedestal (FT-114H) making sure the
holes line up.
5.
Feed the pump cord all the way through the holes in the bowl (FT-114F) and pedestal
(FT-114H) then out of the access door in the base (FT-114I).
6.
FIRMLY
press the stopper into the hole evenly.
a.
Note: Using the handle of a screwdriver or hammer works best to press the
stopper in place.
7.
Position the medium pedestal (FT-305C) over the pump in the large bowl (FT-114G).
8.
Feed the tubing connected to the pump through the top of the medium pedestal (FT-
305C).
9.
Using a hose clamp, secure the loose end of the tubing assembly to the pipe protruding
from the bottom of the medium bowl (FT-305B).
10.
Center the medium bowl (FT-305B) over the medium pedestal (FT-305C).
11.
Fit the finial (FT-305A) into the medium bowl (FT-305B) by feeding the protruding
copper pipe from the bowl into the hole in the bottom of the finial.
12.
Place the pump cover door (FT-114F) into the medium pedestal (FT-305C).
13.
Fill the fountain with water.