Routine maintenance
WARNING!
•
Before any routine maintenance operations, if the harvesting head is assembled on the tool, switch the harve-
ster off (read the power unit manual), disconnect the power supply cable and then remove the head from the
extension pole (11).
•
All maintenance operation not dealt within this manual shall be carried out only by an Authorised Service Points.
Routine maintenance operations can be carried out by the operators.
6.1.1
General
Before any routine maintenance operation:
•
Wear protective gloves.
•
Disconnect the harvesting head from the extension pole (11).
6.1.2
Replacing the teeth
The damaged teeth (1) have to be removed from their seat:
•
Disassemble the teeth holder (7) by removing the 4 screws (6).
•
Put the teeth holder (7) onto a surface and shorten the damaged teeth (1) 2 cm away from the holder.
•
By means of a rubber hammer hit the top of the tooth (1) till it gets out of its seat.
•
Put the new tooth (1) into its seat, being careful to hook the small plastic protrusion to the teeth holder (7) side.
•
Re-assemble the rake (2) onto the oscillator (8).
6.1.3
Cleaning and greasing the harvesting head
Every 200 work hours, open the mechanical head and remove any dust and dirt inside of it. Check the anti-rotation drives (10)
condition and add LISYNT-00-EP spray grease.
WARNING!
Cleaning the harvesting head allows to limit frictions, which would jeopardize tool performance and work auton-
omy.
6.1.4
Storing the tool
Before storing the tool for a prolonged period, carry out the following operations:
•
Take the harvesting head to an Authorised Service Point for being cleaned and greased.
•
Do not expose the tool to rain during the rest period. Store it in its box in a dry place.
Special maintenance
WARNING!
Any special maintenance operation shall be carried out only by an Authorised Service Point.
Periodic maintenance schedule
Maintenance
After the first 8
Work hours
After the first 200
Work hours
At the end of every work season
and/or every 400 work hours
Check the screws for proper tightening
X
Clean the harvesting head and lubricate the
anti-rotation drives with LISYNT-00-EP spray
grease
X
Thorough overhaul by an Authorised Service
Point
X