The fire pit is to be used only with 
the 20 pound, vertical standing 
vapor withdrawal type tank. This 
fire pit is designed to operate on LP 
(Liquefied Propane) gas only. The 
20 lb LP cylinder used with this fire 
pit must conform to the following 
requirements:

• Type 1 Connections
• Diameter - 12” (30.5cm)
• Height - 18” (45.7cm)
• Maximum capacity of 20 pounds

The gas cylinder used must include a 
collar to protect the cylinder valve. 
The cylinder supply system must be 
arranged for vapor withdrawal.

Follow the instructions stated on 
gas cylinder tanks when filling or 
transporting tanks. Failure to do so 
could result in problems relating to 
overfilling, excessive venting release 
of gas and to regulator freezing. 
Never fill the cylinder more than 80 
percent full.

Do not allow dirt or foreign material 
to get into or onto tank connection 
when it is not attached to the fuel 
supply system. Use the protective cap 
provided. Place dust cap on cylinder 
valve outlet whenever the cylinder 
is not in use. Only install the type of 
dust cap on the cylinder valve outlet 
that is provided with the cylinder 
valve. Other types of caps or plugs 
may result in leakage of propane.

Cylinders must be filled before initial 
use. All handling, transport, filling 
and storage of LP gas cylinders 
must be in accordance with NFPA 
58 storage and Handling of Liquid 
Petroleum Gasses, or CAN/CsA 
b149.2 Propane Installation Code.

Cylinders must be suitably tied down 
during transport. Do not place any 
other items on top of cylinders at 
any time. 

Cylinders are not to be exposed to 
excessive temperatures or high heat. 
Refer to the data plate for model 
identification. Units are factory 
equipped for use on only one type 
of fuel. These units cannot be, 
and should not be used on other 
types of fuels. Doing so can cause 
severe damage to the unit and the 
installation area and the added risk 
of serious injury. Any attempt to 
operate this product on fuels for 
which it is not designed voids the 
manufacturer’s warranty.

This unit is not to be utilized with 
a non-self-contained LP-gas supply 
system.

CAUTION

In the connection process, the 
HVR side of the connection 
will seal on the back check in 
the valve, resulting in a slight 
resistance. The connection 
requires about one-half to 
three quarters additional 
turn to complete connection. 
Any fuel supply cylinder 
used must be constructed 
and marked in accordance 
with specifications for 
propane cylinders of 
the U.s. Department of 
Transportation (DOT)CFR 49 
or CAN/CsA B339.

ChECkING FOR lEAkS

1. After all connections are 
completed, check all connections 
and fittings for leaks with a soap 
solution.

2. With all valves closed, apply the
leak check solution (50/50 mix of dish 
washing soap detergent and water) 
to all gas carrying connections and 
fittings.
3. Open tank valve. Presence of 
bubbles at areas of wet solution 
indicates a gas leak. If leaks are 
detected or you smell or hear gas, 
shut off the valve and repair the leak 
or replace the defective part.

Do not use the fire pit until all leaks 
are corrected.

When setting up the fire pit and 
tank, it is recommended to have 
the tank and fire pit on a line 
perpendicular to the wind direction. 
The gas hose/regulator assembly 
should be totally extended to the 
maximum distance so that the hose 
is straight and the tank is as far from 
the fire pit as possible. LP tanks 
are intended for operation in the 
upright position only. Care should 
be taken to protect the fuel supply 
hose from damage from either foot 
or vehicle traffic. If the fire pit is not 
in use, the gas must be turned off at 
the supply cylinder and the cylinder 
should be disconnected from the fire 
pit. storage of the fire pit indoors 

CAUTION 

The gas pressure regulator 
provided with this appliance 
must be used. This regulator 
is set for an outlet pressure 
of 0.5 psi. Replacement 
pressure regulators and 
hose assemblies must be 
those specified by the fire 
pit manufacturer. see rating 
sticker on side of fire pit for 
regulator model number. 
The regulator/hose assembly 
should be handled carefully 
to prevent contamination by 
foreign objects and dirt. The 
assembly should be inspected 
before use and any dirt or 
contamination should be 
wiped off. The hose assembly 
must be replaced prior to the 
appliance being used if there 
is any evidence of excessive 
abrasion or wear, or if the 
hose is damaged. In order to 
insure proper operation, any 
replacement of the regulator 
assembly must be with parts 
authorized by manufacturer. 
Valve/pressure regulators 
are factory set to the correct 
operating pressures. No 
attempts should be made to 
adjust these settings.

CAUTION 

The burner must be inspected 
before each use of the 
appliance. If it is evident 
that the burner is damaged 
it must be replaced before 
the appliance is put into use. 
The burner must be replaced 
only by factory authorized 
parts as specified by the 
manufacturer.

0809-GCLOG-Instructions.indd   7-8

8/19/09   10:11:55 AM