Camille Bauer KINAX N702-SSI Operating Instructions Manual Download Page 12

12

6. Mounting

All inclination transmitter can be mounted either directly
with 3 clamping brackets to the item being measured or with 
a mounting plate with 4 cheese head screws M6. Please take 
care that the installation position of the inclination transmitter 
is perpendicular to the gravity of the earth. The inclination 
transmitter are supplied standard with mounting plate but 
without cheese head screws M6.

•  Avoid impacts or shocks on the housing.

•  Do not deform housing.

•  Do not open or mechanically modify the 

device.

Mounting versions

Drilling aund cut-out diagrams (for mounting transmitters)

dir

ectly with clamps

Ø66.2

[2.606]

115°

130°

115°

M4

50 F8

[1.969]

with mounting plate

60.1

[2.366]

M6

60.1

[2.366]

7. Electric connections

To connect the electrical lines, the inclination transmitter has 
a sensor connector M12x1 / 8 poles.

Readout of positional values

t2

data

clock

t1

T

n clock

t3

Bit 1

Bit 3

Bit n-1

Bit n

Bit 2

Impulse times:

T = 1 to 10 µs / t1 = 0,5 to 5 µs
I2 = < 0,2 µs / t3 = > 12 to 25 µs

PIN confi guration

Pin assignments:

1 = 0 V 
2 = +24 Vs 
3 = Clock + 
4 = Clock – 
5 = Data + 
6 =  Data –
7 =  not used
8 =  not used

1

3

2

8

4

5

6

7

• Do not electricly modify the device nor 

carry out any wiring work when energised.

•  Do not plug in or unplug electric connection 

when energised.

Summary of Contents for KINAX N702-SSI

Page 1: ...camillebauer com N702 SSI Bdfe 157 645 03 01 17 PM1000727 000 01 Betriebsanleitung KINAX N702 SSI Neigungsaufnehmer mit lged mpftem Pendelsystem Mode d emploi KINAX N702 SSI Capteur d inclinaison ave...

Page 2: ...en und nderungen Reparaturenund nderungensindausschliess lich durch den Hersteller auszuf hren Das Ge h use darf nicht ge ffnet werden Bei Eingriffen in das Ger t erlischt der Garantieanspruch n derun...

Page 3: ...bsolute Genauigkeit 0 2 bei 25 C Au sung 14 Bit Einschwingverhalten bei 25 Auslenkung 1 sek Temperaturein uss Ausgangsstrom 30 70 C 0 1 10K 100 5 5 Einbauangaben Material Geh use Kappe 3 2382 Aluminiu...

Page 4: ...l sse Zum Anschliessen der elektrischen Leitungen hat der Nei gungsaufnehmer einen Sensorstecker M12x1 8 polig Auslesen der Positionswerte t2 data clock t1 T n clock t3 Bit 1 Bit 3 Bit n 1 Bit n Bit 2...

Page 5: ...Per Tastendruck kann die Nullposition nach dem Anbau des Ger tes am ausgerichteten Messobjekt justiert werden Die Ausrichtung des Leitungsabganges am Geber kann frei gew hltwerden DereingestellteWinke...

Page 6: ...parations et modifications Lesr parationsetlesmodi cationsdoivent tre effectu es exclusivement par le fabricant Le bo tiernedoitpas treouvert Touteintervention sur l appareil annule la garantie Nous n...

Page 7: ...5 4 Donn es sur la pr cision Pr cision 0 2 25 C R solution 14 bits Comportement en r gime transitoire en cas de d viation de 25 1 sek Variation de temp rature 30 70 C 0 1 10 K 100 5 5 Donn es concerna...

Page 8: ...e et de d coupe pour le montage sur l objet mesurer directement avec des brides de serrage 66 2 1 1 5 130 1 1 5 M4 5 0 F 8 avec plaque de montage 60 1 M6 60 1 7 Raccordements lectriques Le capteur d i...

Page 9: ...t possible d ajuster la position z ro par pression d une touche apr s le montage de l appareil sur l objet de mesure align Il est possible de choisirlibrementl alignementdud partdeligne sur le capteur...

Page 10: ...ir work and modifications Repair work and modi cations shall exclu sively be carried out by the manufacturer Do not open the housing of the device In case of any tampering with the device the guaranty...

Page 11: ...25 tils 1 sec In uence of temperature output current 30 70 C 0 1 10K 100 22 158 F 5 5 Installation data Material Housing cap 3 2382 Aluminium GD AlSi10Mg coated Housing ange 3 2315 Aluminium AlMgSiF30...

Page 12: ...vice Mounting versions Drilling aund cut out diagrams for mounting transmitters directly with clamps 66 2 2 606 1 1 5 130 1 1 5 M4 5 0 F 8 1 9 6 9 with mounting plate 60 1 2 366 M6 60 1 2 366 7 Electr...

Page 13: ...d The initial posi tion can be programmed via keystroke after mounting the KINAX on the aligned object Theinstrumentcanbeelectricallyconnected inanyposition Theadjustedmeasuringrange is symmetrical an...

Reviews: