PM 1001606 000 07
Device handbook CENTRAX CU3000-CU5000
55/106
7.8 Timeouts
Devices with display are designed for displaying measurements. So, any other procedure will be
terminated after a certain time without user interaction and the last active measurement image will be
shown again.
Menu timeout
A menu timeout takes effect after 2 min. without changing the present menu selection. It doesn’t matter if
the currently displayed menu is the main menu or a sub-menu: The menu is closed and the last active
measurement image is displayed again.
Configuration timeout
After 5 min. without interaction in a parameter selection or during entering a value in the settings menu,
the active configuration step is closed and the associated parameter remains unchanged. The next step
depends on what you have done before:
•
If the user did not change configuration parameters before the aborted step, the main menu will be
displayed and the device starts to monitor a possible menu timeout.
•
If the user changed configuration parameters before the aborted step, the query “Store configuration
changes?” is shown. If the user does not answer this query within 2 min. this dialogue is closed: The
changed configuration will be stored and activated and then the last active measurement image is
displayed again.