Configure Menu

The Configure Flow Run 1 screen below 

shows configuration settings for an 

AGA-3 gas run. Required parameters will 

vary, depending on the flow calculation 

method selected (step 6). 

For information on configuring a steam 

flow run, see the ModWorX™ Pro User 

Manual. 

If a liquid turbine input will be used in 

addition to a compensated gas run, click 

on Turbine Input 1 for configuration 

options. 

5

  Set the units of measure-

ment used for volume and rate.

7

  Click “Change Plate” to 

specify plate parameters.

9

  Enter base conditions  

specific to the location.

10

  Click “Change Composition” 

to specify the gas composition.  
(Percentages must total 100%.) 

8

  Specify pipe parameters.

11

  Click OK to save the new 

selections to memory.

4

  Set the calculation period.

1

  Set the instrument date and 

time.

2

  Establish archive settings

•  parameters to be logged
•  contract hour 
•  interval period for saving logs

3

  Configure flow run  

parameters (as shown below).

6

  Click “Change” to select the flow 

calculation method and fluid property 
calculation method  to be used.

From the Configuration 

menu (right), a user can access 

every setting required to 

perform the initial setup for 

the Scanner 2000.

Summary of Contents for NUFLO Scanner 2000 microEFM

Page 1: ...ay need to be adjusted To change the orientation of the head loosen the set screw in the MVT adapter rotate the head no more than 180 degrees and tighten the set screw Remote Mount To install the Scan...

Page 2: ...UP B A TB1 TFM1 I R R I 2 3 4 5 6 1 BLACK RED DIGITAL OUTPUT 13 14 Leave this end of shield disconnected POWER SUPPLY 5 to 30 VDC Resistor may be included in pulse readout device Size the resistor to...

Page 3: ...digit to the left Repeat using UP ARROW LOG and LEFT ARROW DISPLAY to enter all remaining digits Press ENTER SAVE Keypad Configuration Controls Remove the instrument cover to access the keypad Each of...

Page 4: ...is the control center for the Scanner 2000 and provides quick and easy access to the most commonly performed tasks From this screen the user can view real time totals and flow rates input data and sy...

Page 5: ...o perform Then select the parameter you want to calibrate 2 Click Acquire Point to enter a new calibration point and enter the applied calibration value at the prompt Or click Load Calibration From to...

Page 6: ...od used Click Change Task to select a new maintenance task 1 Select the task you want to perform 3 Click Save Changes to save the new parameters to memory 2 Enter new parameters in the fields provided...

Page 7: ...to specify plate parameters 9 Enter base conditions specific to the location 10 Click Change Composition to specify the gas composition Percentages must total 100 8 Specify pipe parameters 11 Click O...

Page 8: ...screen Download Screens Part No 9A 30165024 Rev 03 To download data simply press the Download button and select the range and type of files to be downloaded Daily and interval logs can be viewed or p...

Reviews: