VC Camera Link series
Page 64 of 86
RA14-11A-010
9.4
Command List
Command
Syntax
Value Returned
Description
Help
h
String
Display a list of all commands
Set Read-Out Mode
Get Read-Out Mode
srm 0|1
grm
OK
0|1
0: Normal mode
1: ROI (Region of Interest) mode
(ROI is set using
“sha” and “sva” commands.)
Set Horizontal Area
Get Horizontal Area
sha n1 n2
gha
OK
n1 n2
n1: Starting point of horizontal direction
n2 : End point of horizontal direction
Set Vertical Area
Get Vertical Area
sva n1 n2
gva
OK
n1 n2
n1: Starting point of vertical direction
n2: End point of vertical direction
Set Trigger Mode
Get Trigger Mode
stm 0|1
gtm
OK
0|1
0: Free Run mode
1: Trigger/Overlap mode
Set Trigger Source
Get Trigger Source
sts 1|2
gts
OK
1|2
1: CC1 port input
2: External input
Set Trigger Polarity
Get Trigger Polarity
stp 0|1
gtp
OK
0|1
0: Active low
1: Active high
Set Exposure Source
Get Exposure Source
ses 0|1
ges
OK
0|1
0: Program Exposure (by camera)
1: Pulse Width (by external trigger input)
Set Exposure Time
Get Exposure Time
set n
get
OK
n
n: Exposure Time in
㎲
(Setting range: 10 ~ 7,000,000
㎲
)
Set Analog Gain
Get Analog Gain
sag n
gag
OK
n
n: Analog Gain parameter
(Setting range: 0 ~ 63)
Set Analog Offset
Get Analog Offset
sao n
gao
OK
n
n: Analog Offset parameter
(Setting range: 0 ~ 63)
Set Test Image
Get Test Image
sti 0|1|2|3
gti
OK
0|1|2|3
0: Off
1, 2: Fixed pattern image
3: Moving pattern image
Set Data Bit
Get Data Bit
sdb 8|10
gdb
OK
8|10
8: 8 bit output
10: 10 bit output
Set Strobe Offset
Get Strobe Offset
sso n
gso
OK
n
n: Strobe Offset time in microseconds
(Setting range: 0 ~ 100,000
㎲
,
Only available on VC-25MC/VC-25MC2)
Set Strobe Polarity
Get Strobe Polarity
ssp 0|1
gsp
OK
0|1
0: Active low
1: Active high
Table 9.1 Command List #1