![CAMERA LINK Q-12A65 Operating And Users Manual Download Page 35](http://html.mh-extra.com/html/camera-link/q-12a65/q-12a65_operating-and-users-manual_487777035.webp)
OPERATING AND USER MANUAL QUARTZ SERIES
36
To be able to handle glitches on possible heavily disturbed external trigger signals, a deglitch circuit
can be activated. This deglitch circuit will prevent short glitches to be interpreted as trigger signals.
The sensitivity of the deglitch circuit can be programmed by the DGLT command
Command Syntax:
DGLTx
Command Syntax:
DGLT?
Reply message:
x
where x=0 indicates: deglitch circuit off.
1<x<255: the input signal must be present for at least x
µs, before it will be interpreted as a trigger
signal
. This means that the start of integration is delayed with the set deglitch period. The end of
integration is also delayed with the deglitch period to ensure that the period of the external trigger
signal is the same as the length of the integration time.
Flash Strobe commands
7.5
Flash strobe enable
7.5.1.
The camera is equipped with strobe output signal on the I/O connector. The strobe can be switched on
or off by means of the FSE command.
Command format: FSEx
Command format: FSE?
Return Message: x
where x is set to 0 to disable the strobe output and x is set to 1 to enable the strobe output. The
definition of the active state depends on the strobe polarity.
Flash strobe polarity
7.5.2.
The active state of the strobe output can be inverted to adapt to the application requirements.
Command format: FSPx
Command format: FSP?
Return Message: x
where x is set to 1 for the normal polarity: in this polarity configuration the photo transistor at the
camera output is conductive during the active state of the strobe.
If x is set to 0 the strobe photo transistor is non-conductive during the active state of the strobe.
Output Mode setting
7.5.3.
The strobe output can be operated in two different modes, which are set through the FSM command.
Command format: FSMx
Command format: FSM?
Return Message: x
where x is set to 0 for the automatic mode: The strobe will become active after the sensor is reset and
a configurable delay time is expired. The strobe will deactivate when the acquisition is completed.