K12703 ; 26/43
- 26 -
(7-9) Read out of factory default
This procedure is for reading out the factory default (initial setting before shipment) in order to initialize the setting that was
changed by the user after purchase.
The factory default is shown by the table below.
[Factory default of each register]
Storage area (Register)
Factory default
Program page item
(Stored in each program page)
※
Applied to page A to F
Flag register (FR)
FR = H
’0000
MGC gain set value
(Factory default)
MGC gain correction value
(Factory default)
Offset set value
(Factory default)
Offset correction value
(Factory default)
Direct designated value of shutter speed
H
’0000 (none specified)
Electric shutter table
Contents of table 5-5
Configuration item
(Stored in common area)
Configuration register (CR(H))
CR(H)=H
’0001
Configuration register (CR(L))
CR(L)=H
’2008
Hypothetical shutter switch
0
Hypothetical mode switch
A
ID data
Blank
Vsub voltage set value
(Factory default)
(Note) (Factory default) is the adjusted value for each camera.
[The procedure for restoring the setting to factory default]
①
Transmit
“ e ” command by serial communication.
②
Turn off the power to the camera. Several seconds after that , restore the power.
→
The settings inside the camera (contents of nonvolatile EEPROM) are restored to the factory default of the upper table by this
operation.
(Note) Note that the contents having being set by the user are all lost by executing upper procedures.