2 Electrical Performance and Tests
2.1 Input: DC 5V/2A
2.2 Charging Voltage: 1.48V, 4.2V
2.3 Charging Current :1000mA /500mA
2.4 Cut-off current (at CV mode) : less than 100mA
2.5 Standby current: less than 25mA
3 Mechanical Tests and Requirements
3.1 Drop test
Drop from a height of 3 feet onto a concrete floor covered with 1/8 inch vinyl tile. Drop 3 times
total, each time on a different product surface. After that, test again the appearance, the
insulation function, indicator function and electrical performance.
3.2 Surface
Smooth surface, no scratch, flashes, blot and crack. Hardware gets no rust, flashes and
scratch.
3.3 Vibration Test
The frequency sweep for each item on different surface is 10 times under the condition of the
frequency 10
~
55HZ and the amplitude 0.35mm. After that, test again the appearance, the
insulation function, indicator function and electrical performance.
3.4 Salt Spray Test
Put the unit under temperature 35
with 5% Na
℃
-CI salt spray for 8 hours. Then take out to
dry for 16 hours. After that, test again the appearance, the insulation function, indicator
function and electrical performance.
4 Environmental
Conditions