background image

8 Disposal

 This product, including packaging, is made of different materials that may be recycled.

Please inquire on disposal or recycling systems for the product in compliance with local regulations in force.

 Some electronic components could contain polluting substances, please dispose of properly.

9 Maker’s statement

Assemble the spring-type hinges.

Insert the hinges in the case (on the right or 
left side) and secure them with the screws 
and washers provided.

They must slide in order 
to turn

15 mm~

!!

Snap the cover 
onto the hinges, 
close and secure 
with screws 
provided.

1

2

3

7 Case Cover Assembly

Also, they furthermore represent and warrant that the product/s that are the subject of the present 
Declaration are manufactured in the respect of the following main harmonized provisions:

EN 292 

PART

 1 

AND

 2 

M

ACHINERY

 

SAFETY

.

EN 12453 

 

I

NDUSTRIAL

COMMERCIAL

 

AND

 

OTHER

 

CLOSING

 

MECHANISMS

.

EN 12445 

 

I

NDUSTRIAL

COMMERCIAL

 

AND

 

OTHER

 

CLOSING

 

MECHANISMS

.

EN 12978 

 

S

AFETY

 

DEVICES

 

FOR

 

POWER

 

OPERATED

 

DOORS

 

AND

 

GATES

 ....

EN 60335 - 1   

S

AFETY

 

IN

 

APPARATUSES

 

FOR

 

HOME

 

USE

.

EN 60204 - 1   

M

ACHINERY

 

SAFETY

.

EN 61000 - 6 - 2 

E

LECTROMAGNETIC

 C

OMPATIBILITY

.

EN 61000 - 4 - 4 

E

LECTROMAGNETIC

 C

OMPATIBILITY

EN 61000 - 4 - 5 

E

LECTROMAGNETIC

 C

OMPATIBILITY

IMPORTANT CAUTION!

It is forbidden to market/use product/s that are the subject of this declaration before completing and/or 
incorporating them in total compliance with the provisions of Machinery Directive 98/37/CE

Signatures of the Representatives

MANUFACTURER’S DECLARATION

As per Enclosure II B of Machinery Directive 98/37/CE

Enclosed with the technical documentation (the original copy of the Declaration is available on request)

Date of the present declaration 07/12/2001

The representatives of

CAME Cancelli Automatici S.p.A.

via Martiri della Libertà, 15
31030Dosson di Casier - Treviso - ITALYtel 
(+39) 0422 4940 - fax (+39) 0422 4941
internet: www.came.it - e-mail: [email protected] 

Hereby declare, under their own respons ibility, that the product/s called ...

… comply with the Italian National Legal Provisions that transpose the 
following Community Directives (where specifi cally applicable):

M

ACHINERY

 D

IRECTIVE

 98/37/CE

L

OW

 V

OLTAGE

 D

IRECTIVE

 73/23/EEC - 93/68/EEC

L

ECTROMAGNETIC

 C

OMPATIBILITY

 D

IRECTIVE

 89/336/EEC - 92/31/EEC

R&TTE D

IRECTIVE

 1999/5/CE

TECHNICAL MANAGER 

Mr. Gianni Michielan

MANAGING DIRECTOR

Mr. Paolo Menuzzo

ZT5 - ZT5C

17

A

ll t

h

e d

at

a a

n

d i

n

fo

rm

at

io

n c

o

n

ta

in

ed h

er

ei

n i

s c

o

n

si

d

er

ed s

u

b

je

ct to c

h

an

g

e a

t a

n

y t

im

e a

n

d a

t o

u

r d

is

cr

et

io

n

.

ENGLISH

6.10 Error Messages

 “STOP contact open”: check the correct connection or the efficiency of the device connected.

“Service Test!!!”: There is a malfunction with the connected safety devices.

“Encoder not working: check the correct connection or the efficiency of the device connected.

“CX-CY contact open”: check the correct connection or the efficiency of the device connected.

Summary of Contents for ZT5C

Page 1: ...Control panel for CBXET ZT5 ZT5C INSTALLATION MANUAL...

Page 2: ...tampered with Comply with the distances and diameters of the cables shown in the table in Chap 5 4 Locate the panel in areas protected from accidental blows For the ZT5C version position the panel at...

Page 3: ...16 17 18 3 All the data and information contained herein is considered subject to change at any time and at our discretion ENGLISH 4 3 Main components 1 Display 2 1A fuse for accessories 3 1A fuse fo...

Page 4: ...m between contacts to section power supply Connections inside the case made for protection circuit continuity are allowed as long as they include additional insulation with respect to other internal d...

Page 5: ...er supply accessory 2 x 0 5mm 2 x 0 5mm 2 x 1mm 24V pilot light 2 x 0 5mm 2 x 0 5mm 2 x 1mm 24V in motion output 2 x 0 5mm 2 x 0 5mm 2 x 1mm Safety contacts 2 x 0 5mm 2 x 0 5mm 2 x 0 5mm N O N C contr...

Page 6: ...lamp RS232 cable PC 40 or PC30 Personal Computer Serial communication for PC connection use mod RS235 shielded bipo lar cable with software optional 230V 400V 50 60 H three phase motor Maximum power 7...

Page 7: ...0 11 1 2 3 4 5 7 CX CY TS 3P 7 All the data and information contained herein is considered subject to change at any time and at our discretion ENGLISH 10 11 output 24V A C power supply accessories max...

Page 8: ...ER RSE PROGRAMMING FUNCTION R700 R700 AF AF CONTROL BOARD FUSE ACCESSORIES FUSE LINE FUSE 3 15A S1 GND L N T S L1T L2T CT VS U V W E1 24 0 WARNING Condens CANCELLI AUTOMATICI R700 CANCELLI AUTOMATICI...

Page 9: ...data and information contained herein is considered subject to change at any time and at our discretion ENGLISH 6 1 Description display controls The ENTER key serves to enter the menu confirm and mem...

Page 10: ...ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ESC ENTER PROGRAMMING FUNCTION ESC ENTER PROGRAMMING FUNCTION Procedura Version No manoeuv...

Page 11: ...closing time after the execution of a pedestrian opening operation TIMES 10 sec x 3 Pedestr T C A Courtesy time the courtesy light remains on from 1 to 120 TIMES 10 sec x 3 Courtesy time Functions Aut...

Page 12: ...r disables total stop x 8 FUNCTIONS ON OFF Total stop Service test checks the correct functioning of safety devices and selects the inlets they are connected to x 9 FUNCTIONS OFF Service test Attivo s...

Page 13: ...IO USERS x 5 Reading Delete all to delete all saved users Confirm Y Delete all N RADIO USERS x 6 Calibration Run calibration Adjusts the gate s run and the direction of Opening Closing see pg 14 Veder...

Page 14: ...he adjustment menu select Run adjustment and confirm by pressing ENTER 2 Execute a complete run of opening using to reach the maximum opening point 3 Then confirm by pressing ENTER 4 Execute a complet...

Page 15: ...AM 40 685 AF40 TOUCH 15 All the data and information contained herein is considered subject to change at any time and at our discretion ENGLISH To control the card by radio controls or passes connect...

Page 16: ...t the user whose associated function needs to be changed using the keys to move or press the transmitter key associated with it or swipe the card on the sensor confirm by pressing ENTER 3 Select the f...

Page 17: ...n before completing and or incorporating them in total compliance with the provisions of Machinery Directive 98 37 CE Signatures of the Representatives MANUFACTURER S DECLARATION As per Enclosure II B...

Page 18: ...Cod 319T75 V2 1 11 05 CAME CANCELLI AUTOMATICI CAME UNITED KINGDOM LTD UNIT 3 ORCHARD BUSINESS PARK TOWN STREET SANDIACRE NOTTINGHAM NG10 5BP U K Tel 0044 115 9210430 Fax 0044 115 9210431...

Reviews: