P
age
12
- Manual
FA01359-EN
- 03/2021 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
Command and control devices
1
STOP button (NC contact)
Stop the gate and exclude automatic closing. Use a control device to resume movement.
If the contact is not used, it must be deactivated during programming.
2
Control device (NO contact)
PARTIAL OPENING function
PEDESTRIAN OPENING function
OPEN ONLY function
See function [F8] command 2-3P.
3
Control device (NO contact)
OPEN-CLOSE function
OPEN-STOP-CLOSE-STOP function
OPEN ONLY function
CLOSE ONLY function
See function [F7] command 2-7.
4
Card reader
5
Transponder selector switch
6
Keypad selector
7
Antenna with RG58 cable
1 2 3P 7
A B
S1 GND
7