background image

.   % %3

-

#

.   % %3

-

#

.   % %3

-

#

./ # .#

DIR

TX

RX

TX

RX

Delta

Delta-S

2 5 7 

1 C1 

Pa

g

e

 

6

  

- M

an

u

al

 c

od

31

9

U

3

8

 ve

r.

 

1.

0

 0

9

/2

0

11 © C

A

M

E c

an

ce

lli

 A

u

to

m

ati

ci

 S

.p.

A

. - T

h

e d

ata a

n

d i

n

fo

rm

ati

on

 in

 th

is

 m

an

u

al

 m

ay b

e c

h

an

g

ed at a

ny ti

m

e a

n

d w

ith

ou

t o

b

lig

ati

on

 o

n th

e p

art o

f J

ol

ly M

oto

r S

.r

.l. to n

otify s

ai

d c

h

an

g

es

.

ENGLISH

Lighting and warning devices

Safety devices 

Gate open warning light Contact rated for: 24 V - 3 W Max.

)- Warns of 

open gate position, turns off when gate is closed.

Movement Flasher (contact rated for: 

24V AC - 25W 

Max.) - Flashes while gate opens and closes.

"Reopening when closing (N.C.) Contact»

Input for safety devices like photocells, sensitive 
edges and other devices that comply with EN 12978 
regulations. While the gate is closing, opening the 
contact will invert movement until it is fully openend.

"Reo

 

pening when closing (N.C.) Contact»

 

if unused

Summary of Contents for ZL160N

Page 1: ...CONTROL PANEL FOR 24 V GEARMOTORS English EN INSTALLATION MANUAL ZL160N English EN Z CONTROL PANELS 8 8EN...

Page 2: ...protected by quick fuses see table The card provides and controls the following functions automatic closing after an opening command opening recoil The available command modes are opening closing open...

Page 3: ...1 Dimensions centre distances and anchoring holes 8 2 Main components 1 Connecting terminals 2 1 6 A line fuse 3 3 15A accessories fuse 4 Buttons to memorise radio code 5 Working time adjuster trimmer...

Page 4: ...made for continuity purposes of the protective circuit are fitted with extra insulation compared to other internal conductive parts Set up proper conduits and electric cable raceways making sure these...

Page 5: ...e part of Jolly Motor S r l to notify said changes ENGLISH 6 Electrical connections Gearmotor Power supply Power supply to the 230V AC 50 60 Hz control panel Terminals for powering the 24V AC accessor...

Page 6: ...s Safety devices Gate open warning light Contact rated for 24 V 3 W Max Warns of open gate position turns off when gate is closed Movement Flasher contact rated for 24V AC 25W Max Flashes while gate o...

Page 7: ...ivates upon upon full opening The preset time is adjustabel but it s in any case subject to any safety device intervention and does not activated after a Total Stop or in case of power failure 1 OFF d...

Page 8: ...a and information in this manual may be changed at any time and without obligation on the part of Jolly Motor S r l to notify said changes ENGLISH 9 Activating the radio command Connect RG58 antenna c...

Page 9: ...transmitters you are using AF card Plug in the radio frequency card onto the electronic board AFTER CUTTING OFF THE MAIN POWER SUPPLY or disconnecting the emergency batteries N B The electronic board...

Page 10: ...bligation on the part of Jolly Motor S r l to notify said changes ENGLISH 2 The transmitter button sends the conde and the LED will stay on to signal that memorisation was succesful LED stays lit AF r...

Page 11: ...are made up of various materials Most of these aluminium plastic iron electric cables are solid urban waste These can be disposed of at local solid waste management dumps or recycling plants Other com...

Page 12: ...38019 INDIA CAME India CAME India Automation Solutions Pvt Ltd Automation Solutions Pvt Ltd A 10 Green Park 110016 New Delhi New Delhi 91 11 64640255 256 91 2678 3510 CAME Americas Automation Llc CAME...

Reviews: